7

SECTION VIEW OF THE RIGHT ASSEMBLY


Room ventilation – Location and venting.

ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in
conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be
installed in conformity with the national standards in force.

Conversion to different types of gas

Before carrying out any maintenance work, disconnect the appliance from the gas and electric
supply. For Natural Gas fit regulator assembly described in Fig. 5A. For LP Gas fit assembly
described in fig. 5A.


- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:
To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 6) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.

fig.6

fig.7

TABLE A: Adapting to different types of gas

Gas

NATURAL (A)

LP (E)

Burner

Pressure Inj. size Input Rate Simmer Rate Pressure Inj. size Input Rate Simmer Rate By-pass size

Type

[i.w.c.] 1/100mm [BTU/h]

[BTU/h]

[i.w.c.] 1/100mm [BTU/h]

[BTU/h]

[1/100mm]

Auxiliary

0,90

3400

900

0,54

3400

900

29

Semi-Rapid

1,18

6100

1500

0,70

6100

1500

37

Rapid

4"

1,55

10400

3700

11"

0,92

10400

3700

58

Fish

1,55

10200

4000

0,92

10200

4000

61

Triple Ring

1,65

11900

5300

1,02

12300

5300

73

CAUTION: save the orifices removed from the appliance for future use