4 technical data, 1 general data and operating conditions, Technical data – Lenze P50GAP Manuel d'utilisation

Page 22: General data and operating conditions

Advertising
background image

Technical data

General data and operating conditions

4

22

Lenze ¯ BA_p500 ¯ 3.0

4

Technical data

4.1

General data and operating conditions

General data

Conformity and approval
Conformity

CE

2004/108/EC

EMC Directive

EAC

TP TC 020/2011
(TR CU 020/2011)

Electromagnetic
compatibility of technical
means

Eurasian Conformity
TR CU: Technical Regulation of
Customs Union

Approval

UL

UL 508
CSA C22.2

Process Control Equipment (File−No. E236341)

Other

RoHS

2011/65/EU

Products are lead−free acc. to directive.

Protection of persons and device protection
Enclosure

Front panel

EN 60529

IP65

Rear panel

EN 60529

IP20

Electrical isolation

To the fieldbus

Depending on the MC card used

To the process level

None

Insulation resistance

IEC 61131−2

Protective measures

Against short circuit

EMC
Interference emission

EN 61000−6−4

Class A (industrial premises)

Noise immunity

EN 61000−6−2

Industrial premises
EN 61000−4−2 ESD; severity 3, i.e.

Air discharge: 8 kV,
4 kV with contact discharge

EN 61000−4−3 RF interference (housing)

80 MHz … 1000 MHz, 10 V/m 80 % AM
(1 kHz)

EN 61000−4−4 Burst, severity level 3
EN 61000−4−5 Surge, severity 1
EN 61000−4−6 RF cable−guided

150 kHz … 80 MHz, 10 V/m 80 % AM
(1 kHz)

Operating conditions

Ambient conditions
Climatic

Storage/transport

EN 60721−3−2

2K3:
−25 ... +80 °C depending on the air humidity
(see diagrams

^ 23)

Operation

EN 60721−3−2

3K3:
0 ... +55 °C depending on the air humidity
(see diagrams

^ 23)

Air humidity

EN 60721−3−3

3K3 (without condensation, relative humidity 10 ... 95 %)

Pollution

EN 61131−2

Degree of pollution 2

Mechanical

Vibration

EN 61131−2

1 g

Shock

EN 61131−2

15 g

Site altitude

Storage/transport

< 12000 m amsl

Operation

< 3000 m amsl

Advertising