Operation

Central LED Display

The Belkin PureAV Power Console PF30 is equipped with an LED display
that monitors the vital functions of the Power Console.

A. Power ON indicator light – indicates that the Power Console is

plugged into an AC outlet and is receiving power

B. Wiring OK indicator light – indicates whether the AC outlet to which

the Power Console is connected is wired properly, or cross-wired. If
the Wiring OK indicator does not light, then the hot and neutral wires
are reversed. See page 12 of the Troubleshooting section for more
information.

C. Ground OK indicator light – indicates if the Power Console is

connected to a properly grounded AC outlet. If the Ground OK indicator
does not light, this indicates that the AC wall outlet is not properly
grounded. See page 12 of the Troubleshooting section for more
information.

D. PureFilter Indicator – indicates that the multiphase PureFilter Circuitry

is functioning properly.

Troubleshooting

Power Console is not providing power

Check to ensure that the Power Console is plugged into a properly

grounded AC wall outlet. Some outlets require a wall switch to be
turned on in order to deliver power to the outlet.

Too many devices may be plugged into the Power Console, which are

overloading the unit and tripping the overload circuit breaker. The
Power Console is not designed to handle current loads larger than 15
Amps or 1800 watts. Try unplugging some devices and resetting the
circuit breaker located on the end of the Power Console.

To reset the circuit breaker: Wait at least 10 minutes after the circuit

breaker was tripped before attempting to reset the breaker. Press in
the button located next to the power cord on the end of the unit to
reset. Power should be restored to the outlets on the Power Console.

Your components may be plugged into a “Switched” outlet and the