Dimensions – Bosch WR430-7K Manuel d'utilisation

Page 3

Advertising
background image

3

6 720 606 599

DIMENSIONS

Figure 1

Maximum Hydrostatic water pressure - 1.03 MPa (150 p.s.i.)
Maximum recommended working pressure - 0.69 MPa (100 p.s.i.)
Minimum working pressure - 0.09 MPa (13 p.s.i.) no piping attached
Reccomended pressure for showers and domestic, 0.27 MPa (40 p.s.i.)

The high altitude ratings listed are Canadian Gas Association high altitude ratings and are valid only in Canada. In the U.S., the

National Fuel Gas Code, ANSI Z223.1-1988, recommends for high altitude installations above 2,000 feet, that the input rate be
reduced 4% for each 1,000 feet above sea level. - See page 15.

EXTERIOR

TERMINATION

Model

Type of Gas

Altitude

Input

Size, mm

Qt.

natural gas

130 000 Btu/hr (38 kW)

1.20 diam.

18

propane/LP

125 000 Btu/hr (36.6 kW)

0.79 diam.

18

natural gas

117 000 Btu/hr (34.3 kW)

1.20 diam.

18

propane/LP

112 000 Btu/hr (32.8 kW)

0.79 diam.

18

WR430-7.K..

standard

(0 - 2 000 ft)

high *

(2 000 - 4 500 ft)

Main Burner Orifices

Advertising