Troubleshooting

Problem

Cause

Correction

Pump has following problems: failure
to produce pressure, erratic pressure,
chattering, loss of pressure, low water
volume.

1. Low pressure nozzle installed.

2. Water inlet is blocked.

3. Inadequate water supply.

4. Inlet hose is kinked or leaking.

5. Clogged inlet hose screen.

6. Water supply is over 100°F (38°C).

7. High pressure hose is blocked or

leaks.

8. Spray gun leaks.

9. Nozzle is obstructed.

10. Pump is faulty.

1. Replace with high pressure nozzle.

2. Clear inlet.

3. Provide adequate water flow.

4. Straighten inlet hose, patch leak.

5. Check and clean inlet hose screen.

6. Provide cooler water supply.

7. Clear blocks in outlet hose.

8. Replace spray gun.

9. Clean nozzle.

10. Contact local service facility.

Detergent fails to mix with spray.

1. Detergent shut-off valve is in the

Off” position.

2. High pressure nozzle installed.

1. Rotate detergent shut-off valve to

On” position.

2. Replace with low pressure nozzle.

Engine runs good at no-load but "bogs"
when load is added.

Engine speed is too slow.

Move throttle control to FAST position. If
engine still "bogs down", contact local
service facility.

Engine will not start; or starts and runs
rough.

1. Low oil level.

2. Dirty air cleaner.

3. Out of fuel.

4. Stale fuel.

5. Spark plug wire not connected to

spark plug.

6. Bad spark plug.

7. Water in fuel.

8. Excessively rich fuel mixture.

1. Fill crankcase to proper level.

2. Clean or replace air cleaner.

3. Fill fuel tank.

4. Drain fuel tank; fill with fresh fuel.

5. Connect wire to spark plug.

6. Replace spark plug.

7. Drain fuel tank; fill with fresh fuel.

8. Contact local service facility.

Engine shuts down during operation.

Out of fuel.

Fill fuel tank.

Engine lacks power.

Dirty air filter.

Replace air filter.