Electrical connection, Wiring diagrams, Room ventilation – location and venting – Bertazzoni B3W0..U4X(2 OR 5)D Manuel d'utilisation

Page 5: Conversion to different types of gas

Advertising
background image

5

Electrical connection

The connection of the hobs to mains is effected via the flex and the three pin plug located underneath the
hotplate. The appliance operate at a main voltage of 120V a.c., frequency 60Hz. Electric power absorption is
about 1W for 5 gas burner version or 2W for 6 gas burners version.
WARNING: Electrical Grounding Instructions: This appliance is equipped with a (three-prong)
grounding plug for your protection against shock hazard and should be plugged directly into a
properly grounded receptable. Do not cut or remove the grounding prong from this plug.

Wiring diagrams

Wiring

diagram

description

For hotplate model A see Fig. 11.

1. Cable terminal

For hotplate model B see Fig. 12.

2. Ignition switch
3. Spark generator
4. Ignition spark
L. Black
N. White
T. Green (earth)


Room ventilation – Location and venting.

ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in
conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be
installed in conformity with the national standards in force.

Conversion to different types of gas

Before carrying out any maintenance work, disconnect the appliance from the gas and electric
supply. For Natural Gas fit regulator assembly described in Fig. 5. For LP Gas fit assembly described
in fig. 5.

- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:
To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 7) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.


TABLE A: Adapting to different types of gas
Drop-in cooktop with 5 workyop burners model B3W0..U4X(2 or 5)D

Burner

Position Inj.

size

Gas

Pressure

Max Rate

Min Rate

By-pass size

1/100mm

Type

[i.w.c.]

[BTU/h]

[W]

[BTU/h]

[W]

[1/100mm]

Auxiliary

Front R

0,90

NG

4”

3400

996

900

264

Regulated

0,54

LP(Propane)

11”

3400

996

900

264

0,29

Semi-Rapid

Rear L

1,18

NG

4”

6100

1787

1500

439

Regulated

Rear

R

0,70

LP(Propane)

11”

6100

1787

1500

439

0,37

Rapid

Front L

1,55

NG

4”

10400

3047

3700

1084

Regulated

0,92

LP(Propane)

11”

10400

3047

3700

1084

0,58

Centre

Inner

0,80

NG

4”

2800

820

900

264

Regulated

Dual

0,49

LP(Propane)

11”

2800

820

900

264

0,29

burner

Centre Outer

N°2 x 1,15

NG

4”

12000

3516

5300

1553

Regulated

N°2 x 0,70

LP(Propane)

11”

12000

3516

5300

1553

0,73


Drop-in cooktop with 6 workyop burners model B3Y0..U4X(2 or 5)D

Burner

Position Inj.

size

Gas

Pressure

Max Rate

Min Rate

By-pass size

1/100mm

Type

[i.w.c.]

[BTU/h]

[W]

[BTU/h]

[W]

[1/100mm]

Auxiliary

Front R

0,90

NG

4”

3400

996

900

264

Regulated

0,54

LP(Propane)

11”

3400

996

900

264

0,29

Semi-Rapid

Rear L & C

1,18

NG

4”

6100

1787

1500

439

Regulated

Front

C

0,70

LP(Propane)

11”

6100

1787

1500

439

0,37

Rapid

Front L

1,55

NG

4”

10400

3047

3700

1084

Regulated

0,92

LP(Propane)

11”

10400

3047

3700

1084

0,58

Centre

Inner

0,80

NG

4”

2800

820

900

264

Regulated

Dual

0,49

LP(Propane)

11”

2800

820

900

264

0,29

burner

Centre Outer

N°2 x 1,15

NG

4”

12000

3516

5300

1553

Regulated

N°2 x 0,70

LP(Propane)

11”

12000

3516

5300

1553

0,73

CAUTION: save the orifices removed from the appliance for future use

Advertising
Ce manuel est liée aux produits suivants: