Installation instructions, Electrical requirements – Whirlpool WFL98HEBU Manuel d'utilisation

Page 5

Advertising
background image

5

INsTaLLaTION INsTrUCTIONs

NOTE:

To avoid floor damage, set washer onto cardboard

before moving it.

36"

(914 mm)

1.

Move washer

It is necessary to remove all shipping materials for proper

operation and to avoid excessive noise from washer.
Move washer to within 4 ft (1.2 m) of its final location. It must

be in a fully upright position.

eLeCTrICaL reQUIreMeNTs

n

A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical

supply is required. A time-delay fuse or circuit breaker is

recommended. It is recommended that a separate circuit

breaker serving only this appliance be provided.

n

This washer is equipped with a power supply cord having

a 3 prong grounding plug.

n

To minimize possible shock hazard, the cord must be plugged

into a mating, 3 prong, grounding-type outlet, grounded in

accordance with local codes and ordinances. If a mating outlet

is not available, it is the personal responsibility and obligation

of the customer to have the properly grounded outlet installed

by a qualified electrician.

n

If codes permit and a separate ground wire is used, it is

recommended that a qualified electrician determine that

the ground path is adequate.

n

Do not ground to a gas pipe.

n

Check with a qualified electrician if you are not sure the

washer is properly grounded.

n

Do not have a fuse in the neutral or ground circuit.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected washer:

This washer must be grounded. In the event of a malfunction

or breakdown, grounding will reduce the risk of electrical

shock by providing a path of least resistance for electric

current. This washer is equipped with a cord having an

equipment-grounding conductor and a grounding plug. The

plug must be plugged into an appropriate outlet that is

properly installed and grounded in accordance with all local

codes and ordinances.

WARNING:

Improper connection of the equipment-

grounding conductor can result in a risk of electric shock.

Check with a qualified electrician or serviceman if you are in

doubt as to whether the appliance is properly grounded.
Do not modify the plug provided with the appliance – if it will

not fit the outlet, have a proper outlet installed by a qualified

electrician.
For a permanently connected washer:

This washer must be connected to a grounded metal,

permanent wiring system, or an equipment grounding

conductor must be run with the circuit conductors and

connected to the equipment-grounding terminal or lead on

the appliance.

2.

Locate transport bolts

Locate four transport bolts on rear of washer.

Advertising