Warning, Electrical requirements – Whirlpool UXT5530AAS Manuel d'utilisation

Page 6

Advertising
background image

6

Example vent system

3¹⁄₄" x 10" (8.3 cm x 25.4 cm) Vent System

Example vent system

Electrical Requirements

IMPORTANT: The range hood must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70
(latest edition) or Canadian Electrical Code, CSA C22.1
No. 0-M91 (latest edition).

If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02169-7471

CSA International

8501 East Pleasant Valley Road

Cleveland, Ohio 44131-5575

A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical
circuit is required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this range hood be provided.

This range hood is equipped with a power supply cord having
a 3 prong grounding plug.

To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong, grounding-type outlet,
grounded in accordance with local codes and ordinances. If a
mating outlet is not available, it is the personal responsibility
and obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.

Maximum Recommended Length

= 50 ft (15.2 m)

1 - 90° elbow

= 5.0 ft (1.5 m)

1 - wall cap

= 0.0 ft (0.0 m)

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

Length of 7" (17.8 cm) system

= 13.0 ft (3.9 m)

Vent Piece

3

¹⁄₄" x 10" (8.3 cm x 25.4 cm)

90° elbow

5.0 ft
(1.5 m)

3

¹⁄₄" x 10" (8.3 cm x 25.4 cm)

flat elbow

12.0 ft
(3.7 m)

3

¹⁄₄" x 10" (8.3 cm x 25.4 cm)

wall cap

0.0 ft
(0.0 m)

Maximum Recommended Length

= 35 ft (10.7 m)

1 - 90° elbow

= 5.0 ft (1.5 m)

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

1 - wall cap

= 0.0 ft (0.0 m)

Length of 3

¹⁄₄" x 10" (8.3 cm x 25.4 cm)

system

= 13.0 ft (3.9 m)

Wall cap

90˚ elbow

2 ft (0.6 m)

6 ft (1.8 m)

Wall cap

3

¹⁄₄

" x 10"

(8.3 x 25.4 cm)

elbow

2 ft

(0.6 m)

6 ft (1.8 m)

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death,
fire, or electrical shock.

WARNING