Installation

511250

10

Step 3: (Gas Dryer Only) Connect Gas
Supply Pipe

For further assistance, refer to Section on Gas
Requirements.

1. Make certain your dryer is equipped for use with

the type of gas in your laundry room. Dryer is
equipped at the factory for Natural Gas with a
3/8 inch NPT gas connection.

2. Remove the shipping cap from the gas

connection at the rear of the dryer. Make sure you
do not damage the pipe threads when removing
the cap.

3. Connect to gas supply pipe.

4. Tighten all connections securely. Turn on gas and

check all pipe connections (internal & external)
for gas leaks with a non-corrosive leak detection
fluid.

5. For L.P. (Liquified Petroleum) gas connection,

refer to section on Gas Requirements.

Figure 5

D233I

1

New Stainless Steel Flexible Connector –
Use only if allowed by local codes
(Use Design CSA Certified Connector)

4

Black Iron Pipe
Shorter than 20 ft. (6.1 m) – Use 3/8 in.
(9.5 mm) pipe
Longer than 20 ft. (6.1 m) – Use 1/2 in.
(12.7 mm) pipe

2

1/8 in. NPT Pipe Plug
(For checking inlet gas pressure)

3

Equipment Shut-Off Valve – Install within
6 ft. (1.8 m) of dryer

5

3/8 in. NPT Gas Connection

D233I

1

2

3

4

5