LCD Display

Fault

Possible Cause

Ef

fect on Product

Investigate the Following

Action Required

I

f Fault

Persists.

Blank

* No power

* Key switched of

f

* T

ank

raised

* Emergency stop pressed

* Machine will not operate.

*Key switched of

f

* T

ank

raised

* Emergency stop pressed

* Switch key on (page 8)

* Lower top tank

* Release emergency stop (page

8)

‘OVER CURRENT’

* Brush over current.

* Brush pressure to great.

* Brush current exceeds 32A

* W

rong type of brush for surface

* V

ac. Brush, water &

Detergent

motors / pump will not

operate.

* Brush LED’

s all flash in

unision until the trigger is

released.

* Release brush pressure. ( page 14)

* Changed type of brush.

* Restart machine.

‘UNDER VOL

TS’

* Battery voltage dropped

below

21 V

olts.

* Left most Battery LED

flashes

* Batteries require recharging.

* Faulty cell on battery

* Machine will not operate.

* Battery leads and connections.

* Charge Bartteries. (page 19)

* Replace battery (if cell dam

-

aged)

‘ T

ANK

FULL

* T

ank full requires empty

-

ing.

* W

aste

Tank Float switch activated

whilst

cleaning or of

f aisle mode selected.

* Faulty Float switch.

* V

ac. Brush, water &

Detergent

motors / pump will not

operate.

* T

ank full LED illuminated.

* T

op waste tank full.

* Empty top waste tank

* Replace switch

‘CHARGING’

* Machine on charge.

MACHINE INHIBITED - NO OPERA

TION.

Contact Service Agent.

The

TTV 4555 has a self contained trip meter

, to view the meter turn the key to the ‘On’

position.

Press the mode button to cycle between the dif

ferent modes (fig 56).

T =

Total time.

This meter counts when ever any function is being used, including the of

f asile function (see page 16) .

V =

Vacuum total time.

B =

Brush total time.

W=

W

ater Pump total time.

Fig.56