15

Only use brushes provided with the appliance or those specified in the instruction manual.

The use of other brushes may impair safety.

A full range of brushes and accessories are available for this product.

Only use brushes or pads which are suitable for the correct operation of the machine for the specific task being

performed.

It is essential that this equipment is correctly assembled and operated in accordance with current safety regulations.

When using the equipment always ensure that all necessary precautions are taken to guarantee the safety of the

operator and any other persons who may be affected.

Wear non-slip footwear when scrubbing. Use a respiratory mask in dusty environments.

When cleaning, servicing or maintaining the machine, replacing parts or converting to another function the power

source shall be switched off.

Mains operated machines shall be disconnected by removing the power plug, and battery operated machines shall be

disconnected by switching off the isolating key.

Machines left unattended shall be secured against unintentional movement.

Operators shall be adequately instructed as to the correct use of the machine.

When detergents or other liquids are used, read the manufacturer’s instructions.

Do not allow the supply cord to come into contact with the rotating brushes.

WARNING

Data

Brush Motor

Vac Motor

Power

Noise

Speed

Brush

Dimensions

400 W

300 W

120v 60Hz

71 dB(A)

50Hz = 150rpm

16”

Width - 20.5”

Length - 35”

Height - 44.6”

Gross Weight

Full

Protection Class

Hand Arm

Vibration

Pad

Net Weight

Cleaning

Range

Water Capacity

122.6 lbs

IPX 4

1.4 +/- 0.06ms²

16”

85 lbs

42 m

5 gall

Fluid Flow

tap @40

0

Brush / Pad

Pressure

Cleaning Speed

0.35 LPM

27.4 / 26.2

G/ cm

2

0 - 2.6 mph

TT 516

PROBLEM

CAUSE

SOLUTION

Poor water pick-up

Waste-water tank full
Clogged / blocked vacuum hose
Loose hose connections
Debris basket filter clogged/blocked
Separator filter clogged / blocked
Poor separator seal
Damaged separator seal
Damaged / split vacuum hose
Damaged floor-tool blades

Empty waste-water tank
Remove and clean
Push tight connections
Remove and clean
Remove and clean
Clean and refit
Renew (contact service dept)
Renew (contact service dept)
Renew (contact service dept)

No brush / scrub function

No brushes fitted

Check and fit

Little or no water flow

Clean-water tank empty
Clean-water tank filter blocked/ clogged

Fill clean-water tank
Remove and clean

Trouble-Shooting