trim control allows looped cabinets to be

individually adjusted in level. This is invaluable

in applications where large numbers of

cabinets are used such as in clusters or in trade

show applications (or when EF500P’s are used

as repeater cabinets or for side fill). The 100 Hz

high pass filters allow the EF500P to be used

more efficiently with any active subwoofer.

Features

• Ultra strong plywood cabinet (patterned

after our proven EF508)

• Ultra-clear reproduction throughout the

whole bandwidth

• High efficiency, high tech, 900 Watt Bi-

amped power module

• Superior TX-style processing and

component protection

• True 2 inch Titanium diaphragm horn

driver

• Low distortion/high power-handling 15

inch woofer

• +/- 6 dB Level control (for individual

cabinet level adjustment)

• XLR and TRS inputs / outputs for easy

connection and looping

• Multi-input source mixer for direct inputs
• Direct microphone input with level control
• Two way overall EQ controls
• Integrated flying hardware (3/8 inch

threaded holes)

• Tough, full-length metal grille
• Recessed Mixer panel

Operation

The EF500P is a bi-amped powered full-

range loudspeaker with a built in two

channel mixer. Multiple EF500P cabinets

may be connected through the Link option.

If you’re using the EF500P with an external

mixer, the internal mixer can be disabled.

The built-in mixer has a microphone input

and two (combined) ¼ inch inputs for line

sources such as CD players. Advanced

signal processing is used to give maximum

performance at all levels. There’s a switch

to provide a low frequency rolloff if you’re

going to use the EF500P with a subwoofer.

Mic Input

Any regular microphone can be inserted into

the Mic input. Phantom power is built–in for

condenser microphones.

Line/CD inputs

The Line/CD inputs allow line level sources such

as CD players or Cassette decks to be directly

connected. These inputs are combined to

allow the blending of stereo sources into

mono. The inputs are also balanced to help

reject hum (when used with balanced cables).

This input may be used to allow operation from

lower-level Line inputs (as opposed to the Link

jacks). It may also be used to accommodate

a greater range of level adjustment than the

EF500P Level control allows (for example a

cabinet in a chain of cabinets that needs to

operate at much reduced level).

Link

These parallel jacks allow multiple EF500P

cabinets to be connected together. The Link

Jacks are the correct input to use when driving

the EF500P from an external mixer. The Link

Jacks operate at line level (+4 dBv) to achieve

full power. The EF500P Level control allows

operation at levels from –2 dBv to +10 dBv for

full power. When operating from signals that

are not as strong, use the Line inputs of the

first cabinet in the chain. The Link jacks are

high quality balanced inputs with very good

common mode (hum) rejection. To ensure

maximum hum rejection, the proper balanced

cables must be used. Jacks marked LINK

OUTPUT are connected in parallel with the

LINK INPUTS and are provided for convenience

to connect downstream cabinets. Link inputs

may also be used as outputs and link outputs

may be used as inputs.

Level Control

This control allows cabinets, linked in a chain,

to be individually adjusted over a +/- 4 dB

range.This control does not adjust the level of

the Link jacks.

LF Rolloff

For operation with a subwoofer, the LF Rolloff

switch shuts off the low frequency boost and

filters out signals below 100 Hz. It’s not necessary

to use this switch for speech applications

because the Mic input already has a high pass

filter. This switch only affects the signals to the

internal amplifier and does not affect signals

going out from the internal mixer, or to signals

passing through the Link connections.

MIC

LINE / CD

INPUT

INPUT

OUTPUT

OUTPUT

BAL

LINK

MIXER

MIXER

CLIP

LIMIT

PWR

EF500P

LEVEL

MIC

LINE

/ CD

10

0

TREBLE

BASS

12

12 dB

12

12 dB

10

0

6

6 dB

LF ROLLOFF

0

100Hz

50Hz

MIXER

OFF

ON