3.0 INSTALLATION

3.1 NATURAL GAS

3.2 LP (PROPANE) GAS

!

WARNING

!

WARNING

!

WHEN THE APPLIANCE IS BEING USED WITH THE OPTIONAL TRIPOD, IT MUST BE SITUATED ON A

NON-COMBUSTIBLE SURFACE, NOR CAN IT BE LOCATED BELOW A COMBUSTIBLE OVERHANG.

The log set and the burner assembly are shipped together.

Remove the gas log set and burner assembly and check for damage. DO NOT install damaged components.

The logs are fragile use care when handling.

Place the appliance on a level/secure surface in desired location. This location must be adjacent to the gas

supply line or cylinder.

NOTE: Minimum clearances to combustible construction must be maintained, see "SPECIFICATIONS"

section.

You must have clear and easy access to the on/off valve AFTER the appliance is installed and connected to

the gas supply in order to safely turn off the burner.

THE ON/OFF GAS VALVE IS USED TO TURN THE BURNER ON AND OFF.

Connect the incoming gas supply line to the on/off gas valve of the appliance. Make certain ALL gas connec-

tions are tight, turn the on/off valve at the unit slowly to the on position and use soap water to test for leaks.
DO NOT USE AN OPEN FLAME.

3.2.1 Attach cylinder retaining bracket supplied to the base of the cylinder. Then secure to the surface to

which it sits. Cylinder should be on a level surface.

3.2.2 Make sure cylinder valve is in its full off position. (Turn clockwise to stop).

3.2.3 Check cylinder valve features to ensure it has proper external mating threads. (Cylinder Valve Marked:

USE WITH TYPE 1)

3.2.4 Inspect hose shipped with the unit for damage. Never attempt to use damaged or plugged equipment.

See your local LP Gas Dealer for repairs.

3.2.5 After inspecting the LP hose shipped with the unit, connect the end with the female fitting on the hose

to the male fitting on the on/off gas valve at the end of the flex tube. Tighten fittings using 2 wrenches.

3.2.6 When connecting regulator assembly to the cylinder valve, hand tighten black QCC1 nut clockwise

to a positive stop. DO NOT use a wrench to tighten. Use of a wrench may damage the quick closing

coupling nut and result in a hazardous condition.

3.2.7 Locate the hose out of pathways where people may trip over it or in areas where the hose may be

subject to accidental damage.

3.2.8 Open cylinder valve fully (counter-clockwise). Turn the on/off valve at the unit slowly to the on position

and use a soapy water solution to check all connections for leaks before attempting to light the appli-

ance. If a leak is found, turn tank valve off and do not use the appliance until repairs can be made.