Balboa Water Group Freedom Jets 10-FS715T Manuel d'utilisation

Accessoires pour l'eau Balboa Water Group

Advertising
background image

40729 Rev A July 30, 2009

FREEDOM JET 10-FS711, 10-FS715, 10-FSB11T & 10-FS715T

Specifications

Body:

White PVC

Wall fitting

White ABS

Recommended hole sizes: 2 5/8”

Recommended flow rates

10-FS711/10-FS715:

3 m

3

/h @ 9 m H

2

O

10-FSB11T/10-FS715T:

1.5 m

3

/h @ 7 m H

2

O

Dimensions

10-FS711/10-FSB11T:

32 mm ID air x 32 mm ID water. Drainable

10-FS715/10-FS715T:

32 mm ID air x 50 mm ID water. Non-drainable

Important

Follow the directions for installation and connection. We reserve the right to change the product and the

manual without notice.

Installation

1. Before drilling the 2 5/8” holes to install the jets, make sure the surface is flat so the wall fitting will

have the best surface to seal against.

2. The gasket can be placed on the inside or outside surface of the radius. It may be necessary to in-

stall the gasket on the inside surface to obtain the best seal. Also if the gasket is to be placed on the

outside surface, make sure the surface is smooth enough to seal. A little silicone in both areas will

help the wall fitting and gasket.

3. Before inserting the wall fitting through the hole, use the silicone on the thread area of the wall fitting

only, filling the tread grooves. This will help seal the wall fitting and jet together.

CAUTION: DO NOT PUT SILICONE INSIDE THE JET AS THIS WILL INTERFERE WITH THE

OPERATION OF THE JET.

4. Using the wrench, tighten the wall fitting hand tight. It is not necessary to over-tighten the wall fitting

as the gasket and silicone will create a good seal.

5. After jets are installed on the spa, you can proceed to connect the plumbing. Be sure air lines are

placed in sockets marked “AIR” and water lines are placed in sockets marked “WATER”. Use care

when applying cement inside the slip sockets of the jets. I f you use too much cement, it may be

pushed down into the air and water ports causing interference of the jet operation.

6. Be sure air hoses do not sag. If air hoses sag, the jets may not aspirate properly. You may want to

insert the wall fitting loosely in the jet until all the plumbing is installed and then follow steps 2

through 6.

7. After running the spa for fifteen minutes to clean debris from water hoses, install the directional eye-

ball, adjustable eyeball or Micro’ssage assemblies.

TURN PUMP OFF PRIOR TO INSTALLING OR CHANGING THERAPY OPTIONS.

Note

Use of an air pump to boost the jets is not recommended. The Freedom series is designed to operate

with maximum efficiency without the use of an air pump.

49-10-FS711CEC

ITT HydroAir, February 2006

Advertising
Ce manuel est liée aux produits suivants: