Nl2 l1 l3 p – Indesit KN6C61A(X)-FR Manuel d'utilisation

Page 14

Advertising
background image

14

GB

N

L2

L1

L3

P

• Secure the power supply cable by fastening the

cable clamp screw then put the cover back on.

Connecting the supply cable to the electricity mains
Install a standardised plug corresponding to the
load indicated on the appliance data plate (

see

Technical data table).
The appliance must be directly connected to the
mains using an omnipolar switch with a minimum
contact opening of 3 mm installed between the
appliance and the mains. The switch must be
suitable for the charge indicated and must comply
with current electrical regulations (the earthing wire
must not be interrupted by the switch). The supply
cable must be positioned so that it does not come
into contact with temperatures higher than 50°C at
any point.
Before connecting the appliance to the power
supply, make sure that:

• The appliance is earthed and the plug is compliant

with the law.

• The socket can withstand the maximum power of

the appliance, which is indicated by the data
plate.

• The voltage falls between the values indicated on

the data plate.

• The socket is compatible with the plug of the

appliance. If the socket is incompatible with the
plug, ask an authorised technician to replace it.
Do not use extension cords or multiple sockets.

! Once the appliance has been installed, the power
supply cable and the electrical socket must be
easily accessible.

! The cable must not be bent or compressed.

! The cable must be checked regularly and replaced
by authorised technicians only.

! The manufacturer declines any liability should
these safety measures not be observed.

TECHNICAL DATA

Oven dimensions
(LxDxH)

39x41x34 cm

Volume

Useful
measurements
relating to the oven
compartment

width 42 cm

depth 44 cm

height 23 cm

Power supply
voltage and
frequency

see data plate

Ceramic hob

Front Left

Back Left

Back Right

Front Right
Max. ceramic hob

consumption

1700 W
1200 W

2100 W
1200 W

6200W

ENERGY LABEL

Directive 2002/40/EC on the label of
electric ovens. Standard EN 50304

Energy consumption for Natural
convection – heating mode:

Static

;

Energy consumption for Forced
convection – heating mode:

Fan

Oven;

EC Directives: 06/95/EC dated 12/12/06

(Low Voltage) and subsequent

amendments –
04/108/EC dated 15/12/04

(Electromagnetic Compatibility) and

subsequent amendments –

93/68/EEC dated 22/07/93 and

subsequent amendments –
2002/96/EC.

1275/2008 Stand-by/ Off mode

l 56

N

L3

L1

L2

400V 3N~

H05RR-F 5x2.5 CEI-UNEL 35363

1

3

2

4

5

N

L2 L1

400V 2N~

H05RR-F 4x4 CEI-UNEL 35363

1

3

2

4

5

H05VV-F 4x4 CEI-UNEL 357 46

H05VV-F 5x2.5 CEI-UNEL 35746