Table of burner and nozzle specifications – Indesit KN6G21S(W)-FR Manuel d'utilisation

Page 16

Advertising
background image

16

GB

Table of burner and nozzle specifications

WARNING! The glass lid can

WARNING! The glass lid can

WARNING! The glass lid can

WARNING! The glass lid can

WARNING! The glass lid can
break in if it is heated up. Turn

break in if it is heated up. Turn

break in if it is heated up. Turn

break in if it is heated up. Turn

break in if it is heated up. Turn
off all the burners and the

off all the burners and the

off all the burners and the

off all the burners and the

off all the burners and the
electric plates before closing

electric plates before closing

electric plates before closing

electric plates before closing

electric plates before closing
the lid. *Applies to the models

the lid. *Applies to the models

the lid. *Applies to the models

the lid. *Applies to the models

the lid. *Applies to the models
with glass cover only.

with glass cover only.

with glass cover only.

with glass cover only.

with glass cover only.

! In the case of natural gas, the adjustment screw must
be unscrewed by turning it anti-clockwise.

5. Turn the knob from the MAX position to the MIN
position quickly or open and shut the oven door,
making sure that the burner is not extinguished.

S

S

R

A

TECHNICAL DATA

Oven Dimensions
HxWxD

31x43,5x43,5 cm

Volume

58 l

Useful
measurements
relating to the
oven compartment

width 46 cm

depth 42 cm

height 8,5 cm

Voltage and
frequency

see data plate

Burners

may be adapted for use with any

type of gas shown on the data

plate.

EC Directives 2006/95/EC dated

12/12/06 (Low Voltage) and

subsequent amendments -

04/108/EC dated 15/12/04

(Electromagnetic Compatibility)

and subsequent amendments -

2009/142/EC dated 30/11/09 (Gas)

and subsequent amendments -

90/68/EEC dated 22/07/93 and

subsequent amendments. -

2002/96/EC.

1275/2008(Stand-by/Off-mode)

*

At 15°C and 1013 mbar - dry gas

**

Propane P.C.S. = 50.37 MJ/kg

***

Butane P.C.S. = 49.47 MJ/kg
Natural P.C.S. = 37.78 MJ/m³

Tableau 1

Liquid Gas

Natural Gas

Burner

Diameter Thermal power

kW (p.c.s.*)

By pass

1/100

Nozzle

1/100

Flow*

g/h

Nozzle

1/100

Flow*

l/h

(mm)

Nomin. Réd.

(mm)

(mm)

***

**

(mm)

G20

Fast

(Large)(R)

100

3,00

0,70

41

86

218

214

116

286

Semi Fast

(Medium)(S)

75

1,90

0,40

30

70

138

136

106

181

Auxiliary

(Small)(A)

55

1,00

0,40

30

50

73

71

79

95

Four

-

2.60

1.00

52

78

189

186

119

248

Supply

Pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20

35

37

25

45

20

17

25

K6G2S/FR