SeCtIOn 6 |

troubleshooting

iSSUe

cAUSe

ReMeDy

No LeD DISPLAy

battery voltage too low Pre-charge the battery
The external fuse in
the battery connection
cable has blown.

replace the external fuse

battery is not
connected

1. Unclamp all connections
2. Connect a (new) battery with

the correct polarity

3. reconnect the solar module

and loads

battery is connected
with the wrong
polarity
battery is defective

INfo LeD (1)
fLASheS reD

Charging interrupted
due to excessive
charging current
( > 20A)

Charging automatically continues
as soon as the charging current
lies within the permissible range

LoAD CANNoT be
oPerATeD or oNLy
for A ShorT TIMe
+
INfo LeD (1)
fLASheS reD

Load output is
switched off due to
excessive load current

- reduce load current, if necessary
switch off or disconnect loads
- Check loads

Load output is
switched off due to
short circuit at load
output

- Disconnect loads
- Correct the cause of the short
circuit
- reconnect loads

Load output is
switched off due to
overheating of the
solar charge controller

The load output automatically
switches on again once the solar
charge controller has cooled down
- Improve the cooling air
circulation
- remove any other heat sources
- Check the conditions of use and
the mounting location

LoAD CANNoT be
oPerATeD
+
INfo LeD (1)
fLASheS reD
+
reD bATTery LeD (2a)
fLASheS

Load output is
switched off due to
too low battery voltage

The load output automatically
switches oN again as soon as the
battery voltage lies within the
permissible range
- Pre-charge the battery
- Use additional Low Voltage
Disconnect (LVD) for loads > 20A
that are connected directly to
the battery
- Check the battery and replace
if necessary