Pv + pv - bat + bat – Samlex America SRV-150-30A Manuel d'utilisation
Page 14
14
8
WIRING
PV +
PV -
Bat +
Bat -
PV +
PV -
BAT +
BAT -
PV +
PV -
BAT +
BAT -
Fig 8.2
Ring
terminal
for battery
end
Fig 8.3
Fork
terminal for
Controller
end
Fig 8.1 Wiring Layout
Battery
Inline Fuse
(See Fig 8.4)
Please refer to wiring layout shown in Fig. 8.1. NOTE: Wiring and Fuse sizes recommended below are based on
use of a single 100/150W solar panel with maximum current handling capacity of 10A.
A pair of 20 foot, AWG#12, pre-assembled cables with Multi-Contact (MC4) Male and Female Connectors
is provided to connect the solar panel to the Charge Controller. After making sure that sufficient length is
available to wire the solar panel to the Charge Controller, any excess wire may be used to wire the battery to
the Charge Controller. Please refer to wiring layout at Fig. 8.1 below.
Wiring from Battery to Charge Controller
• Use AWG#12 for up to 6 ft. and AWG#10 for up to 10 ft. to limit voltage drop to 2% at maximum 10A.
• Mark the cables to differentiate between Positive and Negative.
• Make sure the Positive terminal (marked ‘+’) of the battery is connected to the Positive terminal (marked
“BAT +”) of the Charge Controller and the Negative terminal (marked ‘-’) of the battery is connected
to the Negative terminal (marked “BAT -”) of the Charge Controller SCC-30AB (Fig. 8.1). If you are not
sure, use a DC voltmeter to determine the polarity of the battery bank. Reverse polarity connection may
damage the Charge Controller and the resulting damage will not be covered by warranty.
• 4 pieces of Fork Terminals (Fig 8.3) have been supplied for crimping on to the wire ends on the
Controller side. 2 pieces of Ring Terminals (Fig 8.2) have been provided for crimping on the wire ends on
the battery side.
• Use Inline ATC style Fuse Holder of 10A ATC-10 fuse on the battery end of the Positive cable (Fig 8.1; NOT
SUPPLIED). The Fuse Holder comes with 4", AWG#12 pigtails. Splice one pigtail to the Positive wire end
and use the other pigtail for battery connection.
Caution!
1. The battery must be wired to the Charge Controller before the solar panel is
connected to the Charge Controller.
2. Use appropriate size of fuse in battery Positive Cable to protect against fire hazard
due to short circuit in the battery cables.
Solar Panel
Warning:
Be careful not to short the battery
Use inline, 10A ATC Type Fuse with ATC Fuse Holder (Fig. 8.4) as close to the battery as possible.
Fig 8.4
Inline ATC Fuse Holder and ATC-10,
10a Fuse (Not Supplied)
ATC-10
10A Fuse
Fuse
Holder
4" Pigtails, AWG#12