Troubleshooting

PROBLEM: No Input Voltage

Reason Solution

Poor contact with battery
terminals.

Shut down inverter and
disconnect. Clean terminals
thoroughly and reconnect

Blown DC battery fuse(s).

Turn off inverter. Fix problem.
Replace fuse(s) with same type
and rating

PROBLEM: Inverter is Shut Down

Reason Solution
Battery voltage below 10
Volts

Charge or replace battery.

Inverter is too hot (thermal
shut down mode). Red
indicator is lit

Allow inverter to cool. Check
for adequate ventilation. Re-
duce the load on the inverter
to rated continuous power.

Unit may be defective.

See warranty and call
customer service.

PROBLEM: Low Battery Alarm on all the Time

Reason Solution
Input voltage below 11
Volts – buzzing sound

Keep input voltage above 11
Volts to maintain regulation.

Poor or weak battery
condition.

Recharge or replace battery.

Inadequate power being
delivered to the inverter or
excessive voltage drop.

Use lower gage (heavier)
cable. Keep cable length as
short as possible.

PROBLEM: TV does not Work

Reason Solution

TV does not turn on.

Contact TV manufacturer to
find out if the TV is compatible
with a modified sine wave.