Rear Panel ML1500-24, ML2300-24

F. High-Speed Cooling Fans. When the temperature inside the inverter

exceeds a preset limit, the Cooling Fan automatically turns on to cool the

inverter. When the temperature reduces, the fan turns off.

G. Ground Terminal

H. Negative Power Input Terminal.

I. Positive Power Input Terminal.


Determining the DC Power Requirements

Powering multiple appliances from the high-power ML1500-24, ML2300-24

inverter requires a 24 volt battery. To calculate the approximate power in

amps a 24 volt battery bank has to supply you need to know the current, or

amps required for powering the continuous AC load. A shortcut method is to

divide the continuous AC load wattage by 20. For example, the continuous AC

load is 1500 watts / 2300 watts. The current (amps) is: 1500/20 or 45 amps at

24 VDC. Add to the load any DC appliances that may be powered by the

battery bank.

Sizing the Battery

To determine the minimum battery bank ampere-hour rating that you

will need to operate appliances from the inverter, and any DC

appliances powered by the battery bank. Follow these steps: