Maintenance, Draining, Element – State SGV 120 10TS Manuel d'utilisation

Page 7: Element replacement, Anode

Advertising
background image

7

7

A non-adjustable high temperature limit control operates before

steam temperatures are reached. The high limit is in the same

area as the upper thermostat and must be reset manually when

it operates. BECAUSE THE HIGH LIMIT OPERATES ONLY

MAINteNANCe

DRAINING

If the tank is to be shut off and exposed to freezing temperatures,

it must be drained. Water, if left in the tank and allowed to freeze,

will expand and damage the tank.

1. Turn “OFF” the electrical supply to the tank.

WARNING

Make sure the electrical supply to the tank is turned OFF. Failure

to heed this will result in the possibility of DEATH, SERIOUS

BODILY INJURY OR PROPERTY DAMAGE.

2. Open a nearby hot water faucet until the water is no longer hot.

3. Turn the water supply to the solar booster tank off and connect

a hose to the booster tank drain valve to direct the tank water

to a safe location, then open the drain valve.

4. The drain valve must be left open during the shut-down

period.

WARNING

If the steps above are not followed the water passing out of the

drain valve may be extremely hot. To avoid being scalded,

make sure all connections are tight and that the water flow

is directed away from any person.

eleMeNt

In some water areas, scale or mineral deposits will build up

on heating elements. This build up will cause a rumbling

noise. Follow the element replacement directions to remove

the elements from the tank. Soaking in vinegar and scraping

will remove the mineral deposit. Be careful not to bend the

element.

eleMeNt RePlACeMeNt

WARNING

Replacement elements must (1) be the same voltage and

(2) no greater wattage than listed on the model and rating

plate affixed to the tank.
1. Turn OFF the electrical supply to the tank.

WARNING

Make sure the electrical supply to the tank is turned OFF. Failure

to heed this will result in the possibility of DEATH, SERIOUS

BODILY INJURY OR PROPERTY DAMAGE.
2. Drain the tank. Follow the directions for draining.
3. Take off the access panel and turn back the insulation.

Disconnect the wires from the heating element terminals.

4. Remove the element and gasket. You should always use a

new gasket when you replace the element.

5. Install new element.
6. Reconnect the wires as they were.
7. Fill the tank , following the filling directions on page 7. Fill the

tank with water, BEFORE you turn on the electric supply.

ANODe

The anode rod is used to protect the tank from corrosion.

Most hot water tanks are equipped with an anode rod. The

submerged rod sacrifices itself to protect the tank. Instead of

corroding the tank, water ions attack and eat away the anode

rod. This does not affect the water’s taste or color. The rod

must be maintained to keep the tank in operating condition.
Anode deterioration depends on water conductivity, not

necessarily water condition. A corroded or pitted anode rod

indicates high water conductivity and should be checked and/

or replaced more often than an anode rod that appears to be

intact. Replacement of a depleted anode rod can extend the

life of your water heater. Inspection should be conducted by

a qualified technician, and at a minimum should be checked

annually after the warranty period
Sometimes bacteria and mineral action on the anode will make

the water smell. chlorination of water supply will get rid of the

odor. Equipment for treating problem water is available at your

local hardware store.

WARNING

Hydrogen gas can be produced in a hot water system that

has not been used for a long period of time (generally two

weeks or more). Hydrogen gas is extremely flammable and

explosive. To prevent the possibility of bodily injury under

these conditions, open the hot water faucet for several

minutes at the kitchen sink before any electrical appliances

which are connected to the hot water system are used (such

as a dishwasher or washing machine). If hydrogen gas is

present, there will probably be an unusual sound similar to air

escaping through the pipe as the hot water faucet is opened.

There must be no smoking or open flame near the faucet at

the time it is opened.

FIGURe 9

WHEN ABNORMALLY HIGH WATER TEMPERATURES ARE

PRESENT, IT IS IMPORTANT THAT A QUALIFIED SERVIcE

AGENT BE CONTACTED TO DETERMINE THE REASON FOR

OPERATION BEFORE RESETTING.