Troubleshooting

No power at the
sensor

Lights do not
switch ON

breaker has tripped or
is not switched ON

break in wiring
or short circuit

light level setting is in
nighttime mode during
daytime operation

lamp burned out

power is off

breaker has tripped

detection zone not
correctly adjusted

reset breaker, check
wiring with voltage
tester

check for proper
wiring connections

adjust light level
setting

replace lamp

turn power on at
circuit breaker

reset breaker

readjust

Problem

Cause

Remedy

14

Troubleshooting

Lights do not
switch OFF

Lights keep
switching ON/OFF

Lights switch ON
without obvious
movement

abundant heat from the
fi xture’s lamps is within
the detection zone and
keeps lights on as a
result of temperature
change

continuous movement
in the detection zone

switched on light is
within detection zone

sensor is detecting
movement outside of
the lighting zone

mount sensor below
the lamps

readjust zone or
apply shroud

adjust detection
zone or apply
shrouds

adjust zone or apply
shrouds