• Connect drain line to air gap, waste tee or disposer

using the previously determined method. Secure hose
with a screw-type clamp.

Waste Tee Installation

Method 1 – Air gap with waste tee or disposer

Disposer Installation

Waste Tee Installation

Method 2 – “High drain loop” with waste tee or disposer

With this method you will need the drain hose hanger set aside

in Step 1.

Fasten drain hose to underside of countertop with the provided

hanger.

Disposer Installation

Figure Y

Figure Z

IMPORTANT –

When connecting drain line to

disposer, check to be sure that drain plug has been removed.
DISHWASHER WILL NOT DRAIN IF PLUG IS LEFT IN PLACE.

Dishwasher Installation

Remove

Drain

Plug

Tip: Avoid unnecessary service call charges for a no drain
complaint.
Make sure excess drain hose has been pulled through
the cabinet opening. This will prevent excess hose in the
dishwasher cavity from becoming kinked or crushed by the
dishwasher.

18"

Min.

32"

Min.

32"

Min.

18"

Min.

Drain Hose Hanger

11

STEP 17: CONNECT DRAIN LINE (Cont.)

STEP 18: CONNECT POWER SUPPLY

If a power cord with plug is already installed proceed to
Step 19.

In this step you will need the junction box cover and the
#10 Hex head screw from the screws set aside in Step 1.

• Secure house wiring to the back of the junction box with a

strain relief.

• Locate the 3 dishwasher wires, (white, black and green) with

the stripped ends coming out of the AC jumper. Use UL listed
wire nuts of appropriate size to connect incoming ground to
green, white to white and black to black.

• Install the junction box cover using #10 hex head screw.

Check to be sure that wires are not pinched under the cover.

• Make sure that the junction box cover is resting on the

mounting bracket.

WARNING:

If house wiring is not 2-wire with ground, a ground must be

provided by the installer. When house wiring is aluminum, be sure

to use UL-Listed anti-oxidant compound and aluminum-to-copper

connectors.

Figure AA

Ground

(Green)

NOTE: Do not remove the

Junction Box Bracket.

AC

Jumper

Junction Box

Bracket

Black

White

ADVERTENCIA:

Si el cableado doméstico no cuenta con un cable de 2 hilos con

conexión a tierra, un instalador debe realizar una conexión a tierra.

Cuando el cableado doméstico es de aluminio, asegúrese de usar

un compuesto antioxidante y conectores de aluminio a cobre

aprobados por UL.

Ground