Liquid gas, 2 injectors replacement, 3 adjustment of minimum level – Electrolux EGG3322 Manuel d'utilisation

Page 11: 4 electrical connection

Advertising
background image

Liquid gas

Use the rubber pipe holder for liquid gas.
Always engage the gasket. Then continue
with the gas connection.
The flexible pipe is prepared for apply
when:
– it can not get hot more than room tem-

perature, higher than 30°C;

– it is no longer than 1500 mm;
– it shows no throttles;
– it is not subject to traction or torsion;
– it does not get in touch with cutting

edges or corners;

– it can be easily examined in order to

make sure its condition.

The control of preservation of the flexible
pipe consists in checking that:
– it does not show cracks, cuts, marks of

burnings on the two ends and on its full
length;

– the material is not hardened, but shows

its correct elasticity;

– the fastening clamps are not rusted;
– expired term is not due.
If one or more defects are visible, do not
repair the pipe, but replace it.

When installation is complete,
make sure that the seal of each
pipe fitting is correct. Use a soapy
solution, not a flame!

8.2 Injectors replacement

1.

Remove the pan supports.

2.

Remove the caps and crowns of the
burner.

3.

With a socket spanner 7 remove the
injectors and replace them with the
ones which are necessary for the type
of gas you use (see table in "Techni-
cal Information" chapter).

4.

Assemble the parts, follow the same
procedure backwards.

5.

Replace the rating plate (it is near the
gas supply pipe) with the one for the
new type of gas supply. You can find
this plate in the package supplied
with the appliance.

If the supply gas pressure is changeable
or different from the necessary pressure,

you must fit an applicable pressure ad-
juster on the gas supply pipe.

8.3 Adjustment of minimum level

To adjust the minimum level of the burn-
ers:

1.

Light the burner.

2.

Turn the knob on the minimum posi-
tion.

3.

Remove the control knob.

4.

With a thin screwdriver, adjust the by-
pass screw position.

A

A)

The by-pass screw

• If you change from natural gas G20 20

mbar (or natural gas G20 13 mbar

1)

) to

liquid gas, fully tighten the by-pass
screw in.

• If you change from liquid gas to natural

gas G20 20 mbar, undo the by-pass
screw approximately 1/4 of a turn.

• If you change from natural gas G20 20

mbar to natural gas G20 13 mbar

1)

un-

do the by-pass screw about 1/4 of a
turn.

• If you change from liquid gas to natural

gas G20 13 mbar

1)

, undo the by-pass

screw about 1/2 of a turn.

• If you change from natural gas G20 13

mbar

1)

to natural gas G20 20 mbar to

tighten the by-pass screw about 1/4 of
a turn.

WARNING!
Make sure the flame does not go
out when you quickly turn the
knob from the maximum position
to the minimum position.

8.4 Electrical connection

• Make sure that the rated voltage and

type of power on the rating plate agree

1) only for Russia

ENGLISH

11

Advertising