DISCONNECTING THE EXTERNAL UNIT

Notice: the quick-couplers are meant for one-off connection !
The guarantee does not cover multiple installation.

Should it be necessary to disconnect, then go about it as follows:
• ask someone to help you operate the air conditioner via the remote control,
• put the desired temperature at 18 °C
• start the air conditioner, wait until you can also hear the compressor turning
• unscrew the caps from the valves and shut the upper valve (thin duct) with the

socket wrench

• wait up to 1 minute: you will hear the sound of the compressor changing also

shut the lowest valve (thick duct) with the socket wrench

• immediately switch the air conditioner off by taking the plug from the socket
• after both valves have been shut completely put the protective caps back on
• disconnect the same way as indicated for connecting; place the protective caps

on the quick-couplers

Notice: if you are in any doubt or uncertainty leave this work to the installer.