To change from 115V to 230V

11. The motor of this pump is dual voltage and

can run on either 115V or 230V. In general,

230V is more economical to run, and

requires a smaller wire size. Most models

are factory preset to run at 115V.

NOTE: See pump label to verify voltage

prewired at the factory. (

Fig. 11)

12. For 230V service, change the following

wires on the terminal board:

a. Using a pair of needle nose pliers,

pull the gray wire with the female flag

connector from the “A” terminal spade

post. Place it to the right on the “B”

terminal space post. (

Fig. 12a)

b. Pull the red wire with the female flag

connector from the “L2” terminal. Place it

to the left on the “B” terminal space post.

(

Fig. 12b)

A

B

L1

L2

GRAY

RED

12a

A

B

L1

L2

230V

GRAY

RED

12b

c. Reinstall the rear motor cover. (

Fig. 12)

NOTE: To change models from 230V to

115V, simply reverse instructions above.

12c

PUMP ELECTRICAL CONNECTIONS (CONTINUED)

PUMP PRIMING & STARTUP

Shallow Well Application Only:

CAUTION: All pumps must be primed

(filling the cavity with water) before they are

first operated. This may take several gallons

of water, as the suction line will be filled in

addition to the pump cavity.

1. Remove the priming plug with pressure

gauge and air relief plug. (

Fig. 1)

IL1402

Priming plug

with pressure

gauge

Air relief plug

1

2

3

3. Replace air relief plug and continue adding

water to pump cavity until water reaches the

top of the priming plug.

(Fig. 3)

2. Slowly fill pump cavity until water comes out

of air relief hole on top of the pump.

(

Fig. 2)

HP:

1/2

PH

1

Hz

60

Volts

115/230

S.F.

1.2

Amps

6.4/3.2

S.F. Amps:

8.6/4.3

RPM

3450

Type

C

Duty:

Cont.

Temp

65C

KVA Code

G

Frame

56L

Ins Class

B

Factory prewired for 115V

Thermally protected automatic

Check voltage of power source

Use copper conductors only

ELECTRICAL HAZARD

Improper installation may result in fi re, explosion, electrical short or injury. Replace all co

before operating. Ground motor in accordance with local and national electrical codes.

Disconnect power source before touching internal parts. Motors equipped with automati

protec ion may restart without warning.

See instruc ion manual for proper installation procedure.

Se reporter au manuel d’instructions pour suivre la procédure adéquate d’installation.

Consulte el instructive para conocer el procedimiento de instalación correcto

RE

H

11

IL1770

Check Valve

Well Point

4

4. PRIMING NOTE: Several priming attempts

may be necessary, depending on the length

of suction pipe and location of check valve if a

well point is being used.

(Fig. 4)