A-1

INSTALLATION

POWER WAVE

®

455M/STT

®

A-1

SPÉCIFICATIONS TECHNIQUES - POWER WAVE® 455M/STT® (K2203-1)

OUTPUT

TAILLES RECOMMANDÉES DE CÂBLES DʼENTRÉE ET DE FUSIBLES POUR SORTIE NOMINALE MAXIMUM

DIMENSIONS PHYSIQUES

REGISTRES DE TEMPÉRATURES

ENTRÉE À SORTIE NOMINALE – UNIQUEMENT TRIPHASÉE

VOLTS DʼENTRÉE

208/230/460/575V - 60HZ.

200/220/440/575V - 50HZ.

TENSION

DE CIRCUIT

OUVERT

75 VDC

TENSION DʼENTREE /

FREQUENCE

208/50/60HZ
230/50/60HZ
460/50/60HZ
575/50/60HZ

HAUTEUR

26.10 in

663 mm

LARGEUR

19.86 in

505 mm

PROFONDEUR

32.88 in

835 mm

POIDS

293 lbs.

133 kg.

TAILLE DE FUSIBLE SUPERLAG

DE TYPE 75OC OU DISJONCTEUR

(AMPS)

110
100

50
40

FIL DE TERRE DE

TYPE 75OC DANS

CONDUIT TAILLES

AWG

(mm2)

6(16)
6(16)
10(6)
10(6)

FIL EN CUIVRE DE

TYPE 75OC DANS

CONDUIT TAILLES

AWG

(mm2)

4(25)
4(25)
8(10)
10(6)

REGISTRE DE COURANT PAR PROCÉDÉ

MIG/MAG

FCAW

SMAW

Pulse

STT®

COURANT

50-570 Average Amps
40-570 Average Amps
30-570 Average Amps

5-750 Peak Amps

40-325 Amps en Moyenne

REGISTRE DE
TENSION DES

IMPULSIONS

5 - 55 VDC

PUISSANCE AUXILIAIRE

(PROTÉGÉE PAR DISJONCTEUR)

40 VDC AT

10 AMPS

115VAC AT

15* AMPS

REGISTRE DE

TEMPS DʼIMPUL-

SION ET DE FOND

100 MICRO SEC. -

3.3 SEC.

REGISTRE

DE

COURANT/

STT®

5-575/5-325

FRÉQUENCE

DES IMPUL-

SIONS

0.15 - 1000 Hz

COURANT

DʼENTRÉE

AMPS

58/53/25/22
82/78/37/31

49/45/23/18
67/61/31/25

PUISSANCE

AU RALENTI

400 Watts

Max.

FACTEUR DE PUIS-

SANCE À SORTIE

NOMINALE

.95 MIN.

EFFICACITÉ À
SORTIE NOMI-

NALE

88%

CONDITIONS DE

SORTIE

[email protected]%

570A@43V. 60%

[email protected]%

500A@40V. 60%

REGISTRE DE TEMPÉRATURE DE FONCTIONNEMENT

-20°C à +40°C

REGISTRE DE TEMPÉRATURE DʼENTREPOSAGE

-40°C à +40°C

* Les modèles plus anciens fonctionnaient avec un disjoncteur de 10 amps.