Installation – Lincoln Electric IM762 POWER WAVE 455M Manuel d'utilisation

Page 9

Advertising
background image

A-1

INSTALLATION

POWER WAVE 455M

A-1

SPÉCIFICATIONS TECHNIQUES - POWER WAVE 455M (K2202-1, K222-3)

SORTIE

TAILLES RECOMMANDÉES DE CÂBLES DʼENTRÉE ET DE FUSIBLES POUR SORTIE NOMINALE MAXIMUM

DIMENSIONS PHYSIQUES

REGISTRES DE TEMPÉRATURES

ENTRÉE À SORTIE NOMINALE – UNIQUEMENT TRIPHASÉE

VOLTS DʼENTRÉE -

FRÉQUENCE

208/230/460/575V - 60HZ.

200/220/440/575V - 50HZ.

TENSION

DE CIRCUIT

OUVERT

75 VDC

TENSION

DʼENTREE /

FREQUENCE

208/50/60HZ
230/50/60HZ
460/50/60HZ
575/50/60HZ

HAUTEUR

26,10 in

663 mm

LARGEUR

19,86 in

505 mm

PROFONDEUR

32,88 in

835 mm

POIDS

286 lbs.

130 kg.

TAILLE DE FUSIBLE SUPERLAG

DE TYPE 75OC OU DISJONCTEUR

(AMPS)

110
100

50
40

FIL DE TERRE DE TYPE

75OC DANS CONDUIT

TAILLES AWG (IEC)

(MM2)

6(16)
6(16)
10(6)
10(6)

FIL EN CUIVRE DE

TYPE 75OC DANS

CONDUIT TAILLES

AWG (IEC)

(MM2)

4(25)
4(25)
8(10)
10(6)

MIG/MAG

FCAW

SMAW

GTAW

Impulsions

50-570 Amps en Moyenne

40-570 Amps en Moyenne
30-570 Amps en Moyenne
15-500 Amps en Moyenne

5-750 Amps de Crête

REGISTRE DE
TENSION DES

IMPULSIONS

5 - 55 VDC

PUISSANCE AUXILIAIRE

(PROTÉGÉE PAR DISJONCTEUR)

40 VDC À

10 AMPS

115 VAC

À 15* AMPS

REGISTRE DE TEMPS

DʼIMPULSION ET DE

FOND

100 MICRO SEC. -

3.3 SEC.

REGISTRE DE

COURANT

AMPS

5 - 570A

FRÉQUENCE

DES

IMPULSIONS

0.15 - 1000 Hz

COURANT

DʼENTRÉE

AMPS

58/53/25/22
82/78/37/31

49/45/23/18
67/61/31/25

PUISSANCE

AU RALENTI

400 Watts

Max.

FACTEUR DE PUIS-

SANCE À SORTIE

NOMINALE

.95 MIN.

EFFICACITÉ À

SORTIE

NOMINALE

88%

CONDITIONS DE

SORTIE AMPS/VOLTS/FAC-

TEUR DE AMRCHE

[email protected]%

570A@43V. 60%

[email protected]%

500A@40V. 60%

REGISTRE DE TEMPÉRATURE DE FONCTIONNEMENT

-20°C à +40°C

STORAGE TEMPERATURE RANGE

-40°C à +40°C

REGISTRE DE COURANT PAR PROCÉDÉ

COURANT

* Les modèles plus anciens fonctionnaient avec un disjoncteur de 10 amps.

Advertising