8 Troubleshooting

Fault

Cause

Remedy

‡ Motor does not start

> Fuse in mains plug has

blown.

> Overload protection switch

has tripped.

Reset the fuse.

Switch off the vacuum
cleaner and allow it to cool
for approx. 5 minutes. If it
can not be started again,
contact the Alto service
department.

‡ Motor does not run in

automatic mode

1)

> Power tool is defective or not

connected properly.

Check that the power tool
works or that the plug is
inserted correctly.

‡ Acoustic warning

1)

is heard

(reduced suction power)

> Suction power selected with

suction power control

1)

is too

low.

Set suction power in accord-
ance with section 4.2.3.
"Suction power control".

‡ No suction power during wet

cleaning

> Tank is full (floater closes the

suction opening).

Switch off the cleaner. Empty
the tank.

‡ Voltage fluctuations

> Impedance of power supply

is too high.

Connect the cleaner to
another socket closer to the
fuse box. Voltage fluctua-
tions over 7 % should not
occur if the impedance at
the transfer point is

0.15

.

> Hose diameter does not

correspond to suction hose
diameter setting.

Set suction hose diameter
setting

1)

to correspond to

hose diameter.

> Clogged suction hose/

nozzle.

Clean suction hose/nozzle.

> Seal/tank rim between the

upper section of the cleaner
and the dirt tank is dirty/
defective.

Clean/replace seal.

> Filter bag is full.

See section 7.2.2 "Replacing
the filter bag".

> Filter element is clogged.

See section 4.4 "Cleaning
the filter element" and 7.2.3
"Replacing the filter ele-
ment".

1)

Option depending on model

Advertising