CY = Cycle Timer allows a compressor to rest between cycles. Can be

set from 0 to 5 minutes in 1 min increments.

WARNING: A wrong short cycle setting can
damage your equipment. This should only be
changed by a trained HVAC professional.

CL = Calibration offset. Changes the displayed temperature from the

actual temperature by +3 to -3 degrees in one degree increments.

Increasing the offset by +2 will cause the thermostat to display a

temperature that is 2 degrees higher than the actual room.

Creating a Password – Protect the Settings

The buttons on the front of the thermostat can be locked with a password.

To create a password:

1. Press the

and

buttons at the same time and hold them in

for 5 seconds.
You will be asked for a 2 digit password.

2. The digits are set using the

and

buttons to progress

through 00 to 99.

Press the

to move to the next digit. Press

to move back.

3. The password is saved after 5 seconds.

All of the front buttons are now locked out until the password is entered.

Pressing any button will cause

to flash.

To unlock the buttons:

1. Push and hold the

and

buttons for 5 seconds until the

request for password is displayed.

2. Enter the digits for the password by pressing

or

to

progress through the numbers to the password.

3. When the correct password is set, wait for 5 seconds to unlock the

system.

4. If the wrong password is entered the display will flash -- for 5

seconds then return to normal.

Once the security has been disabled, a password needs to be
re-created to protect the settings.