Storage, Technical specifications, Blaze 9e manual – CAMPO EQUIPMENT BLAZE 9E Manuel d'utilisation

Page 5: Maintenance

Advertising
background image

BLAZE 9E MANUAL

MAINTENANCE

WARNING!

NEVER SERVICE THE HEATER WHILE IT IS PLUGGED IN, RUNNING OR HOT. SEVERE BODILY INJURY
OR ELECTRIC SHOCK MAY OCCUR.

ONLY QUALIFIED PERSONS ARE ALLOWED TO OPEN HEATER FOR SERVICE. NO USER-SERVICE-
ABLE PARTS INSIDE.

Keep heater clean. Use pressurized air to blow fan blades clean. Note! Use moderate pressure to avoid
damage to fan blades

Inspect heater before and after each use

The fan motor is sealed and has permanently lubricated bearings

STORAGE

When not in use, the heater must be disconnected from power source, cleaned of dust and stored in a dry
place.

The power supply cord should be loosely wound around the handle of the heater.

TECHNICAL SPECIFICATIONS

HEAT OUTPUT

BTU/Hr

30,700 (9,000W)

AIRFLOW

CFM

550

ELECTRIC CONNECTION

V ac / Hz

240 / 60 single phase

AMPERAGE DRAW

A

36.5

POWER CORD

3x8 AWG

PLUG

NEMA 14-50P

EXTENSION CORD

min. 3x8 AWG

AMBIENT THERMOSTAT

temp. range

32 - 150 °F (0 - 65 °C)

LENGTH

inches

23.5

WIDTH

inches

13.5

HEIGHT

inches

17

WEIGHT

lbs

45

Campo Equipment Co. Ltd. 1 866 323 0042 wwww.campoequipment.com