2 ensure the safety reversing sensors are aligned, 3 ensure the door control is wired correctly, Power – Controlled Products Systems Group 8550C-7 Manuel d'utilisation

Page 22: Ensure the safety reversing sensors are aligned, Ensure the door control is wired correctly

Advertising
background image

22

2

Ensure the Safety Reversing Sensors are aligned

The door will not close if the sensors
have not been installed and aligned
correctly.

When the light beam is obstructed or
misaligned while the door is closing, the
door will reverse and the garage door
opener lights will flash ten times. If the door
is already open, it will not close. The
sensors can be aligned by loosening the
wing nuts, aligning the sensors, and
tightening the wing nuts.

2.1

Check to make sure the LEDs in both sensors are glowing steadily. The LEDs in both sensors will glow steadily if they

are aligned and wired correctly.

Green LED

R

O

S

N

E

S

G

N

I

V

I

E

C

E

R

R

O

S

N

E

S

G

N

I

D

N

E

S

Amber LED

If the receiving sensor is in
direct sunlight, switch it with
sending sensor so it is on the
opposite side of the door.

(invisible light beam)

IF THE AMBER LED ON THE SENDING SENSOR IS NOT GLOWING:

IF THE GREEN LED ON THE RECEIVING SENSOR IS NOT GLOWING:

Make sure there is
power to the garage
door opener.

Make sure the
sensor wire is not
shorted/broken.

RED

WHITE

WHITE

GREY

Make sure the sensor has been wired
correctly: white wires to white terminal
and white/black wires to grey terminal.

Make sure the sensors are aligned.

Make sure the sensor wire is
not shorted/broken.

3

Ensure the Door Control is wired correctly

If the door control has been installed and wired correctly a message will display on the screen.

Power

Advertising
Ce manuel est liée aux produits suivants: