APPLICATION

The LiftMaster

®

Protector System models CPS-RPEN4 and CPS-RPEN4GM, are single-sided safety devices

providing monitored entrapment protection for use with LiftMaster

®

Commercial Door and Gate Operators.

The CPS-RPEN4 and CPS-RPEN4GM may be installed in areas exposed to rain or moisture. The images are for
reference and your product may look different.

Model CPS-RPEN4 (LiftMaster

®

Commercial

Door Operators)

Model CPS-RPEN4GM (LiftMaster

®

Gate Operators)

Logic 4

FDCL Commercial Door Operator

CSL24V Series

RSW12V Series

LA500

Medium Duty Logic

FDOA Commercial Door Operator

CSW24V Series

LA400

FDC Commercial Door
Operator

FDOB Commercial Door Operator

RSL12V Series

LA412

LIFTMASTER

®

PROTECTOR SYSTEM

IMPORTANT INFORMATION ABOUT THE PHOTOELECTRIC SENSOR

Be sure power to the operator is disconnected.
When properly connected and aligned, the photoelectric sensor will detect an obstruction in the path of its
beam. If an obstruction breaks the beam while the door/gate is closing, the operator will stop and typically
reverse to the full open position.
The sensor must be installed so that it faces the refl ector across the entrapment zone, no more than
6" (15 cm) above the fl oor for a door and no more than 27.5" (69.6 cm) above grade for a gate. Minimum
installation width of 5 feet and maximum width of 50 feet. The devices can either be installed on the left or right
of the entrapment zone.
The brackets must be securely fastened to a solid surface such as the wall framing. If installing in masonry
construction, add a piece of wood at each location to avoid drilling extra holes in masonry if repositioning is
necessary.
The invisible light beam path must be unobstructed. No part of the gate or door (or door tracks, springs,
hinges, rollers or other hardware) may interrupt the beam while the door/gate is closing.

CARTON INVENTORY

Photoelectric Sensor. . . . . . . . . . . . . . . . . . . . . . . (1)
Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . (2)
Refl ectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (2)

Refl ectors Support Bracket . . . . . . . . . . . . . . . . . . (1)
Installation Instruction . . . . . . . . . . . . . . . . . . . . . (1)
Self-tapping Screws . . . . . . . . . . . . . . . . . . . . . . . (4)

To prevent possible SERIOUS INJURY or DEATH from a closing door or gate:
• Be sure to DISCONNECT POWER to the operator BEFORE installing the photoelectric sensor.
• The door or gate MUST be in the fully opened or closed position BEFORE installing the LiftMaster

®

Monitored Entrapment Protection device.

• Correctly connect and align the photoelectric sensor.
• Install the photoelectric sensor beam NO HIGHER than 6" (15 cm) above the fl oor for door and

27.5" (69.8 cm) above grade for gate operators.

LiftMaster

®

Monitored Entrapment Protection devices are for use with LiftMaster

®

Commercial Door

and Gate Operators ONLY. Use with ANY other product voids the warranty.

• Entrapment protection devices MUST be installed per the operator owner's manual for each Entrapment