2.

Remove the glass light lens from the grill by pulling downward
on the lens. It is held in place with hidden tabs on either side
of the lens. It might be necessary to carefully insert a putty
knife or screwdriver into one of the indentations around the
light lens to help release the lens from the grill (Figure 8).

3.

Plug cord from lamp holders into the appropriate receptacle
(Figure 9).

4.

Line up the slots in the grill with clips on the inside of housing.
Insert included #8 screws through lockwasher (both located
inside bag attached to underside of grill), through grill slots and
into housing clips. Tighten both screws until the grill fits snugly
to the ceiling. DO NOT OVER TIGHTEN (Figure 10).

CAUTION:

FAILURE TO SECURE THE GRILL MAY RESULT

IN A RATTLING OR HUMMING NOISE.

5.

Install a 100 watt maximum, type A19 medium base
incandescent bulb (not included) and a 7 watt maximum
type C7 (candelabra base) night light (not included) into the
side lamp holder (Figure 11).

SECTION 5

Wiring

CAUTION:

MAKE SURE POWER IS SWITCHED OFF AT

SERVICE PANEL BEFORE STARTING INSTALLATION.

CAUTION:

ALL ELECTRICAL CONNECTIONS MUST BE

MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES,
OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR
WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE
THE SERVICES OF A QUALIFIED ELECTRICIAN.

1.

Run wiring from an approved wall switch carrying the
appropriate rating. One neutral (white), one ground (green
or bare copper), and three hot (black, blue, brown leads
connected to the switch, one for each function). Secure the
electrical wires to the housing with an approved electrical
connector. Make sure you leave enough wiring in the box to
make the connection to the fan’s receptacle.

2.

From where you have access to the fan’s junction box, connect
the white wire from the house to the two white wires from the
fan. Connect one hot (black) wire from the wall switch to the
black wire from the fan (this is the fan control). Connect second
hot (blue) wire from the wall switch to the blue wire from the
fan (this is the main light control). Connect the third hot (brown)
wire from the wall switch to the brown wire from the fan (this
is the night light control). Connect the ground wire (green or
bare copper) from the house to the green wire from the fan
(Figure 6). Use approved methods for all connections.

SECTION 6

Completing the Installation

1.

Reinstall the fan’s venturi by holding it at approximately a 45
degree angle, hook the two tabs on the venturi into the slots
on the housing and secure in place by tightening the venturi
screw. Rotate the blower wheel by hand to ensure it spins
freely. Now plug the fan motor into the receptacle (Figure 7).