3 dimensions – VEGA POINTRAC 31 Profibus PA Manuel d'utilisation

Page 57

Advertising
background image

57

11 Annexe

POINTRAC 31 • Profibus PA

43835-FR-130822

Priorité

Description selon norme

Profibus

User Error Codes

État NE-107

24

Conflict in MGC

121, 122, 141

FAILURE

23

Communication Error in

MGC

8

FAILURE

22

MGC-Slave reports Error

38

FAILURE

21

Undefined 21

-

-

20

Undefined 20

-

-

19

Undefined 19

-

-

18

Detector Temperature cri-

tical

125

OUT_OF_SPEC

17

Error while Auto-Standar-

dization

73

FAILURE

16

Excessive Radiation

123, 124

FAILURE

15

Input out of Bounds

13

OUT_OF_SPEC

14

Error while Signal Pro-

cessing

68

FAILURE

13

Undefined 13

-

-

12

Undefined 12

-

-

11

Undefined 11

-

-

10

Undefined 10

-

-

9

Undefined 9

-

-

8

Undefined 8

-

-

7

AITB Simulated

29

FUNCTION CHECK

6

Undefined 6

-

-

5

Undefined 5

-

-

4

Undefined 4

-

-

3

Undefined 3

-

-

2

Undefined 2

-

-

1

Error while Trend Recor-

ding

126, 127

GOOD

0

Undefined 01

-

-

Not displayed

33, 45, 71, 86

GOOD

Remarque:

L'état NE-107 préréglé dans la version livrée n'est qu'une recommandation. Vous pouvez

adapter ces réglages selon le profile PA 3.02. Voir DIAG_EVENT_SWITCH.

11.3 Dimensions

Les dessins cotés suivants ne représentent qu'une partie des versions possibles. Vous pouvez

télécharger des dessins cotés détaillés sur www.vega.com/Téléchargements et " Dessins ".