Ret ard – MSD 6530 Digital Programmable 6AL-2 Installation User Manual

Page 12

Advertising
background image

12

INSTALLATION INSTRUCTIONS

M S D  

•   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4

STEP RETARDS

There is a single step retard that is controlled

through the Pink activation wire or through rpm.

It can also have an rpm point that the engine must

reach before the retard becomes active (a minimum

rpm can also be programmed that must be reached

before a step becomes active). A time based ramp

can be programmed to gradually bring the retard

to its full On amount, or to ramp the retard amount

out (back to no retard) from its setting.

Activation through Wiring: The retard is

activated when 12 volts are applied to the

Pink wire. The maximum retard allowed by the

ignition is a total of 30° (including other retard

amounts or a boost map).
Activation through RPM: The step retard can

also be activated through rpm. In order to achieve

this, 12 volts must still be applied to the Pink wire,

and an rpm value must be selected from the Step

RPM menu. When 12 volts are applied, the retard

will not activate until the rpm value is reached. Note

that the retard will remain active above this rpm.

It will deactivate when the rpm drops below the

set amount or when 12 volts are removed from

the Pink wire.

Note: If you prefer to activate the step retard through

the activation wire and not rpm, then the rpm

value of the retard step menu must be set

to 800 rpm.

Step Retard Ramp: The retard step can be

ramped to and from its full retard amount

over a time based program (Figure 12). It is

adjustable from 0-2.5 seconds in 0.01 second increments. Default is zero for both On and Off.

RPM: The minimum engine rpm that must be reached before a step retard is activated.

On: The amount of time it takes for the step retard to reach its Retard Degree. Allows a gradual

ramp On time to reach the Retard Degree. User adjustable from 0.00 to 2.50 sec. (0.01 sec.

increments).

Off: The amount of time it takes for the step to retard to reach NO retard. Allows a gradual ramp

Off time to reach NO Retard. User adjustable from 0.00 to 2.50 sec. (0.01 sec. increments).

Deg: The amount of retard.

Note: All of the retard amounts are cumulative and the maximum amount of retard is 30°.

TIME

RET

ARD

ON

OFF

FULL RETARD

RAMPED

ON

OFF

FULL RETARD

ON

RAMPED

OFF

FULL RETARD

On and Off Retard Step, No

Ramping

FULL RETARD

Ramping the Retard On

and Off

Ramping the Retard Off

Ramping the Retard On

RAMPED

ON

RAMPED

OFF

Figure 12 Different Retard Activation Options.

Advertising