Adapting the hob to different types of gas, Regulating the minimum flame, Setting of the gas burners – Candy PG 750 DC X Manuel d'utilisation

Page 17: Screws regulating

Advertising
background image

GB

IE

31

ADAPTING THE HOB TO DIFFERENT TYPES OF GAS

To adapt the Hob for use with different types of gas, carry out the following instructions:
— remove the grids and burners
— insert the hexagonal spanner (supplied) into the burner support (Fig. 6)
— unscrew the injector and replace it with one suitable for the gas to be used (see

Table of gas consumption)

— carry out regulation of the burner.

A) As illustrated, as-
semble parts in se-
quence:
A) fixed pipe
B) washer
C) Elbow fitting with

tapered thred
connection

2) Tighten the joints
with the Spanners,
remembering to twist
the pipes into position.

3) Attach fitting C to
mains gas supply us-
ing rigid copper pipe
or flexible steel pipe.

IE

GB

Please note
Some models are equipped with both conical and cylindrical connectors for gas supply.
Please select the type which is correct for the supply concerned.

To prevent any potential damage to the hob please carry out the installation following
this sequence:

Fig. 5

A

B

Hexagonal spanner

Fig. 6

Cylindrical
(but connector)

Tapered thread conical

32

GB

IE

REGULATING THE MINIMUM FLAME

After lighting the burners, turn the control knob to the minimum setting and then remo-
ve the knob (this can easily be removed by apply a gentle pressure).
Using a small «Terminal» type screwdriver the regulating screw can be adjusted as in
Fig. 9. Turning the screw clockwise reduces the gas flow, whilst turning it anticlockwise
increases the flow – Use this adjustment to obtain a flame of approximately 3 to 4 mm
in length and then replace the control knob.
When the gas supply available is LPG (Bottle gas)- the screw to set the idle flame must
be turned (clockwise) to the end stop.

Screws regulating

(for differend models)

Fig. 9

Fig. 7

Fig. 8

BURNER

BURNER CAP

AIR REGULATION

SCREW

FIXING

SCREW

SMALL

MEDIUM

LARGE

DOUBLE RING

MAXI

FISH

For dimensions «X» see table of gas consumption

SETTING OF THE GAS BURNERS

When the jets have been changed it is necessary to set the correct air gap by keeping
to the setting “X” as shown in the table “ gas consumption” fig 7. Warning the value of ‘
X ‘ setting varies in relation to the size of gas burner and type of gas chosen.
A good flame must be of medium length (fig.8B), excessive air will cause the flame to
be short and with sharp colour (fig.8C): in this case it is necessary to extend out the tu-
be for the air setting from the burner body, if there is insufficient air the flame will ap-
pear weak and long (fig. 8A): in this case push the tube of the air setting back into the
burner body. To adjust the air setting tube loosen the retaining screw.
Once the air is correctly set secure the screw over the tube ( fig. 7).

reg.

air

4 mm

2 mm

15 mm

13 mm

15 mm

Working

burner

large

medium

maxi

double ring

fish

Ø gas jet

1/100 mm

120

93

2x94

2x94

2x94

Ø gas jet

1/100 mm

80

61

2x65

2x65

2x65

STD. Dim

kW

2,65

1,5

3,3

3,3

3,3

l/h

G20

252

143

314

314

314

g/h

G30

193

109

238

238

238

g/h

G31

189

107

236

236

236

Qn
kW

2,5

1,45

3,1

3,1

3,1

l/h

G25

277

161

343

343

343

min.Dim

kW

0,65

0,38

0,9

0,9

0,9 G30

1 G20/G25

reg.

air

4 mm

2 mm

15 mm

13 mm

15 mm

reg.

air

2 mm

5 mm

0 mm

0 mm

0 mm

G20

G30

G25

G31

G30
G31

G20/G25

G20 20mbar

G30 29mbar

G31 37mbar

G25

25mbar

X dimension according

to Gas type

Table of gas consumption

1W = 0,860 kcal/h

reg.

air

5 mm

7 mm

15 mm

15 mm

15 mm