Installation – electrical connection – Candy PVD 756 HLX Manuel d'utilisation

Page 49

Advertising
background image

- 49

INSTALLATION – ELECTRICAL CONNECTION

«The installation receiving the appliance referred to must comply with the standard in force

in the installation country».

The Candy Group does not accept any responsibility if this provision is not complied with.

Caution:

• Before connecting, check the power supply voltage shown on the meter, the

circuit breaker setting, the fuse rating and the earth continuity of the installation.

• The electrical connection to the mains must use an earthed socket outlet, or pass

though an all-pole cutting device having a minimum contact opening distance of 3

mm.

If the appliance has a socket outlet, it must be installed so that the socket outlet is

accessible.

• The green/yellow protection wire must be linked to the earth terminals, of the

appliance on one side, and the installation on the other side.

• We cannot be held responsible for any incident or its consequences that may arise

during the use of an appliance not linked to the earth, or linked to an earth whose

continuity is defective.

• All work in relation to the power supply cable must be carried out by the after

sales service or someone with similar qualifications.

The ceramic hob comes without power supply cable. It is equipped with a terminal board

for selecting the type of electrical connection appropriate to the installation.

The terminal board has several connection options:

. Single phase

220 -240 V AC

. Two phase

220-240 V2 AC

. Three phase

220-240 V3 AC

. Three phase

380-415 V3N AC

Advertising
Ce manuel est liée aux produits suivants: