REGULATING THE MINIMUM FLAME

After lighting the burners, turn the control knob to the minimum setting and then remo-
ve the knob (this can easily be removed by apply a gentle pressure).
Using a small «Terminal» type screwdriver the regulating screw can be adjusted as in
Fig. 9. Turning the screw clockwise reduces the gas flow, whilst turning it anticlockwise
increases the flow – Use this adjustment to obtain a flame of approximately 3 to 4 mm
in length and then replace the control knob.
When the gas supply available is LPG (Bottle gas)- the screw to set the idle flame must
be turned (clockwise) to the end stop.

Screws regulating

(for differend models)

27

Fig. 9

Fig. 7

Fig. 8

BURNER

BURNER CAP

AIR REGULATION

SCREW

FIXING

SCREW

SMALL

MEDIUM

LARGE

DOUBLE RING

MAXI

FISH

For dimensions «X» see table of gas consumption

SETTING OF THE GAS BURNERS

When the jets have been changed it is necessary to set the correct air gap by keeping
to the setting “X” as shown in the table “ gas consumption” fig 7. Warning the value of ‘
X ‘ setting varies in relation to the size of gas burner and type of gas chosen.
A good flame must be of medium length (fig.8B), excessive air will cause the flame to
be short and with sharp colour (fig.8C): in this case it is necessary to extend out the tu-
be for the air setting from the burner body, if there is insufficient air the flame will ap-
pear weak and long (fig. 8A): in this case push the tube of the air setting back into the
burner body. To adjust the air setting tube loosen the retaining screw.
Once the air is correctly set secure the screw over the tube ( fig. 7).

air

regul.

4 mm

2 mm

13 mm

15 mm

Working

burner

large

medium

double ring

maxi

Ø injector

1/100 mm

120

93

2x94

2x94

Ø injector

1/100 mm

80

61

2x65

2x65

Qn
kW

2,65

1,5

3,3

3,3

l/h

G20

252

143

314

314

g/h

G30

193

109

238

238

g/h

G31

189

107

236

236

Qn
kW

2,5

1,45

3,1

3,1

l/h

G25

277

161

343

343

Qmin.

kW

0,650

0,380

0,900

0,900

air

regul.

4 mm

2 mm

13 mm

15 mm

air

regul.

2 mm

5 mm

0 mm

0 mm

G20

G30

G25

G31

G30
G31

G20/G25

G20 20mbar

G30 29mbar

G31 37mbar

G25

Quota «X» depending on type of gas

Table of gas consumption

1W = 0,860 kcal/h

air

regul.

5 mm

7 mm

15 mm

15 mm

GB

IE

28

When you have carried out the new gas regulation, replace the old gas rating pla-
te on your appliance with one (supplied with hob) suitable for the type of gas for
which it has been regulated.

USE OF HOB

USER INSTRUCTIONS

This appliance must only be used for the purpose for which it is intended, domestic
cooking, and any other use will be considered improper and could therefore be danger-
ous. The Manufacturer will not be responsible for any damage or loss resulting from
improper use.

USING THE GAS BURNER

To ignite the burners, place a lighted taper close to the burner, press in and turn the
control knob anti-clockwise.
If the burners have not been used for a couple of days, wait for a few seconds before
lighting the burner, this will allow any air present in the pipes to escape.
For appliances fitted with electronic ignition carry out the following:
• push in and turn the knob anticlockwise to the

symbol.

• ignite the burner by pressing the sparker button.
For hobs fitted with automatic ignition simply push in and turn the knob to the

sym-

bol.
The ignition system will continue to generate sparks as long as the gas tap is being
pressed.
If the burner is not ignited within 5 seconds, turn the knob to the 0 position and repeat
the operation.
For models fitted with a safety tap (which cuts-off the flow of gas if the flame is acci-
dentally extinguished) the burners are ignited ad described above, but care must be
taken to keep the knob pressed in for 5 or 6 seconds after the flame is ignited.

ATTENTION: Prior to switching on the gas hob ensure that the burners and bur-
ner caps are correctly placed within their position.

GENERAL ADVICE
For the best results, the flat-bottomed pans size should match the gas burner size as
follows. See fig. pag. 21.
— Front right burner

from 12 to 18 cm.

— Front left burner

from 12 to 18 cm.

— Back right burner

from 18 to 24 cm.

— Back left burner

from 24 to 26 cm.

For smaller containers the gas burner should be regulated so that the flame does not
overlap the base of the pan. Vessels with concave or convex base should not be used.
WARNING: If a burner is accidentally extinguehed, turn the knob to the off posi-
tion and do not attempt to re-ignite if for at least 1 minute.
To protect the glass lid from damage and in the interests of safety, the burners/plates
must be turned off and the burner/pan support/plate area must be cool before closing
the lid down.