19

Remove any objects from the pump impeller

by rotating it.

Put the cap back on the emergency emptying

hose and place the latter back in its seat.

Screw the pump

cover fully in.

Close the pump

door.

IMPORTANT!

When the appliance is in use and depending

on the programme selected there can be hot

water in the pump.

Never remove the pump cover during a wash

cycle, always wait until the appliance has

finished the cycle, and is empty. When

replacing the cover, ensure it is securely

retightened so as to stop leaks and young

children being able to remove it.

Cleaning the water inlet filter

If your water is very hard or contains traces of

lime deposit, the water inlet filter may become

clogged. It is therefore a good idea to clean it

from time to time.

Turn off the water tap.

Unscrew the water

inlet hose. Clean the

filter using a hard

bristle brush.
Tighten up the inlet

hose.

The dangers of freezing
If the machine is exposed to temperatures

below 0°C, certain precautions should be taken.

Turn off the water tap.

Unscrew the inlet hose.

Place the end of the emergency emptying

hose and that of the inlet hose in a bowl

placed on the floor and let water drain out.

Screw the water inlet hose back on and

reposition the emergency emptying hose

after having put the cap on again.

When you intend to start the machine up

again, make sure that the room temperature

is above 0°C.

IMPORTANT!
Every time you drain the water through the

emergency emptying hose you must pour 2

litres of water into the main wash compartment

of the detergent drawer and then run the drain

programme. This will activate the ECO VALVE

device avoiding that part of the detergent

remains unused at next washing.

Emergency emptying out
If the water is not discharged, proceed as

follows to empty out the machine:

pull out the plug from the power socket;

close the water tap;

if necessary, wait until the water has cooled

down;

open the pump door;

place a bowl on the floor and place the end

of the emergency emptying hose into the

bowl. Remove its cap. The water should

drain by gravity into the bowl. When the bowl

is full, put the cap back on the hose. Empty

the bowl. Repeat the procedure until water

stops flowing out;

clean the pump if necessary as previously

described;

replace the emergency emptying hose in its

seat after having plugged it;

screw the pump cover again and close the

door.