NOTE: The foam strip helps keep the underside of the
cooktop frame free from debris and helps the cooktop sit flat
on uneven counters.

Install Cooktop

1. Remove the 2 screws located in each side of the cooktop

burner box.

2. Attach the 2 hold-down brackets to the burner box.

3. Install the cooktop into the countertop cutout by tilting one

end of the cooktop into the cutout, then lowering the other
end into the cutout.

4. Assemble hold-down screws to hold-down bracket. See the

following illustration.

5. Center the cooktop in the opening and, using a wood block

between the screw and the countertop, moderately tighten
the screws to secure cooktop.

IMPORTANT: Do not tighten screws directly against the
countertop.

Make Gas Connection

To Assemble Pressure Regulator:

1. Using 2 or more people, stand the cooktop on its side or

back.

2. Connect the flexible stainless steel connector to the pressure

regulator using a

¹⁄₂" male pipe thread adapter.

A combination of pipe fittings must be used to connect the
cooktop to the existing gas line. Shown following is a typical
connection. Your connection may be different, according to
the supply line type, size and location.

3. Install the pressure regulator with the arrow pointing up

toward the bottom of the burner box and in a position where
you can reach the regulator.

A. Burner box
B. Foam strip

C. Stainless steel frame
D.

¹⁄₁₆

" (1.6 mm)

A. Countertop
B. Wood block

C. Hold-down screw
D. Hold-down bracket

E. Burner box

A

B

C

D

A

B

C

D

E

A. Gas pressure regulator
B. Up arrow - Regulator must be installed with

arrow pointing up at cooktop bottom.

C. Adapter - Must have

¹⁄₂

" male pipe thread

D. UL listed or CSA approved flexible stainless

steel gas supply line

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.

Examples of a qualified person include:

licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.

Failure to do so can result in death, explosion, or fire.