Determine vent length – Whirlpool 3RAWZ481E Manuel d'utilisation

Page 6

Advertising
background image

6

NOTE: The following kits for close
clearance alternate installations are
available for purchase. Please see the
“Assistance or Service” section of this
manual to order.

• Over-The-Top Installation:

Part Number 4396028

• Periscope Installation (For use with dryer

vent to wall vent mismatch):

Part Number 4396037 – 0 cm to 45.72
cm (0 in. to 18 in.) mismatch

Part Number 4396011 – 45.72 cm to
73.66 cm (18 in. to 29 in.) mismatch

Part Number 4396014 – 73.66 cm to
127 cm (29 in. to 50 in.) mismatch

2. Determine vent length.

The maximum length of the exhaust
system depends upon:

• The type of vent (rigid metal or flexible

metal).

• The number of elbows used.

• The type of hood.

recommended hood

styles

10.2 cm

(4")

10.2 cm

(4")

louvered

hood

box hood

angled

hood

10.2 cm

(4")

6.4 cm

(2-1/2")

acceptable style

See the exhaust vent length chart that
matches your hood type for the
maximum vent lengths you can use.

Exhaust systems longer than specified
will:

• Shorten the life of the dryer.

• Reduce performance, resulting in

longer drying times and increased
energy usage.

3. Determine the number of elbows you will

need.

Determine Vent Length

1. Select the route that will provide the

straightest and most direct path
outdoors. Plan the installation to use the
fewest number of elbows and turns.
When using elbows or making turns,
allow as much room as possible. Bend
vent gradually to avoid kinking. Avoid
90° turns.

better

good

NOTE: Side and bottom exhaust
installations have a 90° turn inside the
dryer. To determine maximum exhaust
length, add 1 90° turn to the chart.

Number of

90° turns or

elbows

0

1

2

3

4

Type of

metal vent

rigid

flexible

rigid

flexible

rigid

flexible

rigid

flexible

rigid

flexible

Box or

Louvered

hoods

20 m

(64 ft.)

11 m

(36 ft.)

16.5 m

(54 ft.)

9.4 m

(31 ft.)

13.4 m

(44 ft.)

8.2 m

(27 ft.)

10.7 m

(35 ft.)

7.6 m

(25 ft.)

8.2 m

(27 ft.)

7 m

(23 ft.)

Angled

hoods

17.7 m

(58 ft.)

8.5 m

(28 ft.)

14.6 m

(48 ft.)

7 m

(23 ft.)

11.6 m

(38 ft.)

5.8 m

(19 ft.)

8.8 m

(29 ft.)

5.2 m

(17 ft.)

6.4 m

(21 ft.)

4.6 m

(15 ft.)

Vent Length Chart

IMPORTANT: Do not use vent runs longer
than those specified in the Vent Length
Chart.

The following chart helps you determine
your maximum vent length based on the
number of 90° turns or elbows you will
need and the type of vent (rigid or flexible
metal) and hood that you will use.

Advertising