Determine vent length and elbows needed for best drying

performance

Use the Vent system chart below to determine type of vent

material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in the

Vent system chart. Exhaust systems longer than those

specified will:

Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and

increased energy usage.

The Vent system chart provides venting requirements that will help

to achieve the best drying performance.

Vent system chart

NOTE: Side exhaust installations add a 90º turn inside the dryer.

To determine maximum exhaust length, add one 90º turn to the

chart.

InstallVentSystem

1. Install exhaust hood. Use caulking compound to seal exterior

wall opening around exhaust hood.

2. Connect vent to exhaust hood. Vent must fit inside exhaust

hood. Secure vent to exhaust hood with 4" (102 mm) clamp.

3. Run vent to dryer location. Use the straightest path possible.

See “Determine vent path” in “Plan Vent System.” Avoid 90º

turns. Use clamps to seal all joints. Do not use duct tape,

screws, or other fastening devices that extend into the interior

of the vent to secure the vent, because they can catch lint.

LevelWasher/Dryer

Properly leveling your washer/dryer avoids excessive noise and

vibration.
1. Check the levelness of the washer/dryer by placing a level

on the top edge of the washer, first side to side, then front

to back.

2. If the washer/dryer is not level, prop up the front with the

wood block and adjust the feet up or down as necessary.

Remove wood block.

3. Tilt the washer/dryer forward until the rear of the washer/dryer

is at least 4" (102 mm) off the floor. You may hear the self-

adjusting rear feet click into place. Lower the washer/dryer to

the floor. Check the levelness of the washer/dryer with a level

as shown above.
If washer/dryer will not level, recheck rear leveling legs for free

movement as described in the “Install Leveling Legs” section.

Repeat until the washer/dryer is level.
NOTE: It may be necessary to level the washer/dryer again

after it is moved into its final location.

4. After the washer/dryer is in its final location and is level, use an

adjustable or open-end wrench to turn the nuts on the front

feet tightly against the washer cabinet.
If the nuts are not tight against the washer cabinet, the

washer/dryer may vibrate.

MakeGasConnection

1. Remove the red cap from the flexible gas connector.
2. Remove the ½" NPT adapter from the flexible gas connector

(it will be necessary to use two adjustable wrenches).

3. Install the adapter on the ½" rigid gas supply pipe using pipe-

joint compound.

NOTE: For LP gas connections, you must use pipe-joint

compound resistant to the action of LP gas. Do not use

TEFLON

®†

tape.

Number of

90º turns

or elbows

Type of Vent

Box or

Louvered

hoods

Angled

hoods

0

Rigid metal

37 ft (11.3 m)

35 ft (10.7 m)

1

Rigid metal

32 ft (9.7 m)

27 ft (8.2 m)

2

Rigid metal

24 ft (7.3 m)

19 ft (5.8 m)

A. ½" rigid gas supply pipe
B. Use pipe-joint compound.

C. ½" NPT adapter
D. Do not use pipe-joint compound.

E. Flexible gas connector

B

A

C
D

E

†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.