Technical rep – White Rodgers SSC1000 Manuel d'utilisation

Page 5

Advertising
background image

5

!

W

W

W

W

WARNING

ARNING

ARNING

ARNING

ARNING

Do not attempt repair of this unit unless you are

Do not attempt repair of this unit unless you are

Do not attempt repair of this unit unless you are

Do not attempt repair of this unit unless you are

Do not attempt repair of this unit unless you are
familiar with the necessary tools, equipment, utility

familiar with the necessary tools, equipment, utility

familiar with the necessary tools, equipment, utility

familiar with the necessary tools, equipment, utility

familiar with the necessary tools, equipment, utility
connections and potential hazards.

connections and potential hazards.

connections and potential hazards.

connections and potential hazards.

connections and potential hazards.

Repair should be performed only by a qualified

Repair should be performed only by a qualified

Repair should be performed only by a qualified

Repair should be performed only by a qualified

Repair should be performed only by a qualified
service provider.

service provider.

service provider.

service provider.

service provider.

Failure to do so could result in reduced performance

Failure to do so could result in reduced performance

Failure to do so could result in reduced performance

Failure to do so could result in reduced performance

Failure to do so could result in reduced performance
of the unit, serious personal injury or death.

of the unit, serious personal injury or death.

of the unit, serious personal injury or death.

of the unit, serious personal injury or death.

of the unit, serious personal injury or death.

TECHNICAL REP

TECHNICAL REP

TECHNICAL REP

TECHNICAL REP

TECHNICAL REPAIR GUIDE

AIR GUIDE

AIR GUIDE

AIR GUIDE

AIR GUIDE

This guide contains service checks to assist service personnel
in locating and correcting any malfunction that might occur to
render the air cleaner ineffective or inoperative. The air cleaner
has been designed with replaceable components, such as the
high-voltage power supply and air flow switch. This allows the
serviceman to replace a faulty component rather than attempt
repairs of such components in the field.

SER

SER

SER

SER

SERVICE INDICA

VICE INDICA

VICE INDICA

VICE INDICA

VICE INDICATION

TION

TION

TION

TION

SER

SER

SER

SER

SERVICE CHECKS

VICE CHECKS

VICE CHECKS

VICE CHECKS

VICE CHECKS

Control switch “ON”

Unit functioning Nor

Unit functioning Nor

Unit functioning Nor

Unit functioning Nor

Unit functioning Normall

mall

mall

mall

mally

y

y

y

y.....

Fan operating
Operating Light ON

Control switch “ON”

1.

1.

1.

1.

1. P

P

P

P

Po

o

o

o

ow

w

w

w

wer is not being supplied to air c

er is not being supplied to air c

er is not being supplied to air c

er is not being supplied to air c

er is not being supplied to air cleaner

leaner

leaner

leaner

leaner.....

Fan not operating

A. Check fuse or circuit breaker.

Operating Light OFF

B. Make sure that grille is closed and safety switch is pushed in.

Excessive arcing during

1.

1.

1.

1.

1. Collecting cell dir

Collecting cell dir

Collecting cell dir

Collecting cell dir

Collecting cell dirty

ty

ty

ty

ty.....

normal operation –

A. Clean cell thoroughly as instructed in this manual.

Operating Light may blink

2.

2.

2.

2.

2. W

W

W

W

Wet collecting cell.

et collecting cell.

et collecting cell.

et collecting cell.

et collecting cell.

A. Allow cell to dry after cleaning before applying power.

NO

NO

NO

NO

NOTE

TE

TE

TE

TE: Occasional arcing

3.

3.

3.

3.

3. Ex

Ex

Ex

Ex

Excessi

cessi

cessi

cessi

cessiv

v

v

v

ve airbor

e airbor

e airbor

e airbor

e airborne ma

ne ma

ne ma

ne ma

ne material.

terial.

terial.

terial.

terial.

or “snapping” is considered

A. Additional air cleaner(s) may be required in extreme environments.

normal.

B. Additional clean make-up air may be required.

4.

4.

4.

4.

4. Dama

Dama

Dama

Dama

Damag

g

g

g

ged or shor

ed or shor

ed or shor

ed or shor

ed or shorted collecting cell.

ted collecting cell.

ted collecting cell.

ted collecting cell.

ted collecting cell.

A. Inspect cell for bent plates. Straighten plates as necessary.
B. Check for foreign objects shorting across cell plates or ionizing section.
C. Inspect cell for loose or broken ionizing wire(s). Replace as needed.
D. Inspect cell for cracked or broken insulator(s), around cell perimeter.

Replace collecting cell if condition persists.

5.

5.

5.

5.

5. Dama

Dama

Dama

Dama

Damag

g

g

g

ged c

ed c

ed c

ed c

ed char

har

har

har

harcoal filter

coal filter

coal filter

coal filter

coal filter.....

A. Remove charcoal filter. If arcing/snapping stops, the filter may be

breaking down and require disposal or replacement.

Control switch “ON”

1.

1.

1.

1.

1. Dama

Dama

Dama

Dama

Damag

g

g

g

ged or shor

ed or shor

ed or shor

ed or shor

ed or shorted collecting cell.

ted collecting cell.

ted collecting cell.

ted collecting cell.

ted collecting cell.

Fan operating

A. Remove collecting cell. Close exhaust grille so safety switch is pushed

Operating Light OFF

in. If Operating light comes ON with cell removed, check cell as
described above. If light does not come ON, proceed to next step.

2.

2.

2.

2.

2. P

P

P

P

Po

o

o

o

ow

w

w

w

wer Suppl

er Suppl

er Suppl

er Suppl

er Supply

y

y

y

y.....

A. Remove collecting cell. With safety switch pushed in, 120 VAC should

be present at terminals marked “LINE” on power supply. If voltage is
below 6100 VDC at red high voltage terminal on power supply, replace
power supply. If voltage is correct, replace indicator light.
NO

NO

NO

NO

NOTE

TE

TE

TE

TE: Unit may require up to one hour of operation to reach indicated

voltage when first installed or when replacing cell.

Advertising