Prepare the hood

For vented installations, go to
Step 11.

For non-vented installations,
go to “Make electrical
connection”.

3-1/4" x 10" (8.3 x 25.4 cm)

RECTANGULAR VERTICAL

vent system

5

4.

From the diagrams below,

select the diagram for your
installation.

Vented installations: Cut the vent
system and electrical wiring
access holes as required.

Non-vented installations: Cut only
the one 1-1/4" (3.2 cm) dia. wiring
access hole required. If wiring
through the top, use location
shown in VERTICAL vent systems.
If wiring through the back, use
location shown in HORIZONTAL
vent system.

5.

Set the hood on a protective

covering such as cardboard or a
large towel. Remove the 7"
(17.8 cm) round duct plate from
top of hood. Set duct plate and
mounting screws aside.

1-1/4"
(3.2 cm)

5"
(12.7 cm)

centerline

wall

5-1/4"
(13.3 cm)

7-1/2"
(19.1 cm)

2"
(5.1 cm)

1-1/4"
(3.2 cm)
dia. hole

3-1/4" x 10" (8.3 x 25.4 cm)

HORIZONTAL

vent system

1/8"
(3.2 mm)

3-3/4"
(9.5 cm)

centerline

cabinet

front

5-1/4"
(13.3 cm)

7-1/2"
(19.1 cm)

3/4"
(19 mm)

1-1/4" (3.2 cm)
dia. hole

7" (17.8 cm)

ROUND VERTICAL

vent system

5"

(12.7 cm)

centerline

wall

7-1/2"
(19.1 cm)

2"
(5.1 cm)

1-1/4"
(3.2 cm)
dia. hole

8" (20.3 cm)
dia. hole

7" (17.8 cm)
round duct
plate

6.

Remove tape holding

standard filters in place. Remove
both filters. Insert flat blade
screwdriver into slots in filters.
Push each filter toward back of
hood, lift out and set aside.
For non-vented installations: With
the special blue and yellow strips
facing towards the cooking
surface, attach the charcoal filters
to the aluminum filters.

filter
slots

flat blade
screwdriver

7.

Remove damper/vent

connector from inside the hood.
Set connector, mounting screws
and parts bag aside.

damper/vent
connector

8.

Remove wiring cover from

inside the hood. Set cover and
mounting screw aside.

wiring
cover

9.

Depending on your

installation, remove either top or
back wiring knockout and install a
U.L.- or CSA-listed strain relief.

strain
relief

10.

For vented installations,

remove either top or rear
rectangular knockout. If using 7"
(17.8 cm) round vent, remove both
top rectangular knockout and the
semi-circular knockout.

rear
rectangular
knockout

top rectangular knockout
(also remove if using
7" (17.8 cm) round vent)

semi-circular
knockout
(remove for
7" (17.8 cm)
round vent)

Excessive Weight Hazard

Use two or more people to move
and install range hood.

Failure to do so can result in
back or other injury.

WARNING