3-1/4" x 14"
(8.3 cm x 35.6 cm)
to 9" (22.9 cm)
= 4.5 ft. (1.4 m)

90° elbow =
5 ft. (1.5 m)

45° elbow =
2.3 ft. (0.8 m)

9" (22.9 cm) to
3-1/4" x 14"
(8.3 cm x 35.6 cm)
= 1 ft. (0.3 m)

3-1/4" x 14"
(8.3 cm x 35.6 cm)
to 9" (22.9 cm)
90° elbow =
5 ft. (1.5 m)

9" (22.9 cm) to
3-1/4" x 14"
(8.3 cm x 35.6 cm)
90° elbow =
5 ft. (1.5 m)

Recommended standard
fittings

Installation steps

1.

Put on gloves and safety

glasses. Place cardboard or another
form of protection on top of a flat
surface where you can easily
assemble the downdraft vent
system. Remove parts packages,
downdraft vent and blower box
from carton. Remove all shipping
materials, tape and protective film
from downdraft vent and blower
box.

4.

Attach support legs to side of

downdraft vent with two screws in
each leg. Do Not tighten screws.

Excessive Weight Hazard

Use two or more people to move
and install downdraft vent.

Failure to do so can result in back
or other injury.

WARNING

7.

Attach damper plate

(supplied with exterior blower
system) to front of downdraft vent
using 4 hex washer nuts.

5.

Carefully insert downdraft

vent into countertop cutout. Two
people are recommended to
support the weight of the
downdraft vent during lifting.
Check that downdraft vent is
parallel to side of cutout and that
mounting brackets rest gently on
countertop.

6.

Move support legs down

against cabinet floor. Place a level
against front of downdraft vent
base and adjust position of legs
until downdraft is level vertically.
Use a pencil to mark the top of
each leg on face of downdraft vent.
Then mark location of support leg
mounting holes on cabinet floor.
Remove downdraft vent from
cutout. Drill starter holes at each
mounting screw location on
cabinet floor. Align top of legs with
pencil marks on face of downdraft
vent. Tighten screws in legs.

8.

Remove the 2 Phillips-head

screws attaching the wiring box
cover. Determine which direction
(rear or down) electrical connection
will need to run from appliance
wiring box. Remove cover. Knock
out rear or lower wiring opening in
wiring box.

Power supply cable needed
between exterior blower assembly
and blower box is not provided.

9.

Determine the location where

the exterior blower box will be
located. Cut opening in roof or wall
for vent system to exterior blower.
Install exterior blower.

Wall Installations

• Use caulking compound between
mounting flange and wall.

Roof Installations

• Follow standard roofing

procedures.

• The flashing sheet should be

entered over the roof opening.

• Lower edge of flashing should lie

on top shingles and upper edge
underneath shingles.

• Seal assembly between roof, fan

and flashing with roofing mastic
to prevent leaks.

10

3.

Attach the left side and right

side end caps to the downdraft.
Use 1 screw with each end cap.

2.

Attach the left side and

right side overcounter support
brackets to the downdraft. Use 1
screw with each bracket.

over counter
support arm

support leg

mark

level

end cap