Caution – White Rodgers 1F30(W) Manuel d'utilisation

Page 4

Advertising
background image

CALIBRATING THERMOMETER ON

THERMOSTAT COVER

If thermometer reading on cover does not match
thermostat:
1. Remove thermostat cover.

2. Set cover on table near an accurate thermometer.

3. Allow at least 10 minutes for thermometer to sense

room temperature.

4. If the thermometer readings are different, insert a small

screwdriver blade into the thermometer shaft in the
back of the cover. Adjust until the cover thermometer
matches the other thermometer (see Fig. 5).

5. Replace thermostat cover.

CALIBRATING THERMOSTAT

This thermostat has been carefully adjusted at the factory
and should not require recalibration.

Due to enivronmental conditions, during normal operation
there may be a few degrees difference between the
indicator setting of the thermostat and actual room
temperature. If the disagreement is appreciable, however,
first make sure that the thermostat is properly located and
leveled. Then, if recalibration still seems necessary,
proceed as follows:

CAUTION

To prevent electrical shock and/or equipment
damage, disconnect electric power to system
until recalibration is complete.

1. The anticipator's heat may adversely affect thermostat

recalibration. To prevent this, disconnect electrical
power to thermostat at furnace, main fuse, or breaker
box.

2. Move temperature adjustment lever to a setting about

5

°

above room temperature.

3. Remove thermostat cover. Slip 7/32" wrench onto hex

nut beneath bimetal. While holding temperature
adjustment lever stationary, turn hex nut clockwise
until mercury shifts to right end of tube (see Fig. 6).

4. Move temperature adjustment lever to lowest setting.

5. Replace thermostat cover. Wait 10 minutes for bimetal

temperature to stabilize. Do not stand near thermostat
during this period as your breath and body heat will
affect bimetal temperature.

6. Move temperature adjustment lever to correspond to

actual room temperature. Then remove thermostat
cover.

7. Slip 7/32" wrench onto hex nut. While holding

temperature adjustment lever stationary, turn hex nut
counterclockwise until mercury just barely shifts to left
end of tube (see Fig. 6).

8. Replace cover and set thermostat to desired

temperature. Turn on electrical power to system.

7/32" Calibration

Wrench

Bimetal

Temperature

Adjustment

Lever

Figure 6. Calibrating Thermostat

Figure 5. Calibrating Thermostat Thermometer

Back Side of Thermostat Cover

Thermometer

Adjustment

Advertising