Specifications – Rinnai EX17C Manuel d'utilisation

Page 4

Advertising
background image

4

Rinnai Corporation EX17C / EX22C Manual

EX17C EX22C

Application

For manufactured home (USA only) or mobile home or residential installation convertible
for use with natural gas and liquefied petroleum gases (propane / LPG) when provision is
made for the simple conversion from one gas to the other.
For commercial setting.
For installation at altitudes up to 10,200 feet (3109 m).

General Description Forced combustion, forced convection, flued gas furnace

Operation

Push button electronic

Gas Connection

1/2 in male NPT

Gas Control

Electronic

Burners

Stainless steel Bunsen burner

Temperature Control Electronic thermostat, (Low, 60-80ºF in 2ºF increments, High)

Ignition System

Electronic spark ignition

Flue System

The flue must be terminated to atmosphere with only flue components listed with the
appliance’s certification. Warranty will be voided if non listed components are installed.

Humidifier Tray

Capacity - 2.1 pints (1000 cc)

Electrical Connection AC 120V, 60 Hz, 46 watts

AC 120V, 60 Hz, 56 watts

Standby Power

0.5 watt

Weight

Noise Level

33-38 dB

33-42 dB

AFUE Rating

Natural Gas: 81% Propane: 82%

Natural Gas: 80% Propane: 82%

57 lbs (26 kg)

Specifications

Rinnai is continually updating and improving products. Therefore, specifications are subject to change without
prior notice.

The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating
conditions and was determined independently of any installed system.

Safety Features

Overheat: The appliance will automatically shut

down when the appliance exceeds a predetermined
temperature.

Flame Failure: The appliance will automatically

shut down if the burner flame is extinguished.

Power Failure: The appliance will shut off the gas

if it loses electrical power.

Power Surge Fuse: A glass fuse on the PC board

protects against overcurrent. If the fuse blows then
all indicator lamps will be off.

Spark Detector: The appliance automatically

shuts down if there is an abnormal spark at ignition.

Fusible Link: In case the overheat feature does

not prevent an overheat then the fusible link could
break, shutting off the appliance.

Appliance Specifications