Product dimensions, Cutout dimensions, Before you start – Philips Double Oven Manuel d'utilisation

Page 2: Warning danger, Tool needed: parts supplied, Double oven single oven, Single oven undercounter, Double oven cabinet side view single oven

Advertising
background image

Page 1

4 screws (double oven)

Phillips
screwdriver

Product dimensions

Cutout dimensions

Before you start...

49-1/2"

(125.7 cm)

recessed

height

51"

(129.5 cm)

max.

overall

height

28-3/8"

(72.1 cm) max.

recessed width

23"
(58.4 cm)
max.
recessed
depth

Double oven

Single oven

27-1/2"
(69.9 cm)
recessed
height

28-3/8"

(72.1 cm) max.

recessed width

23"
(58.4 cm)
max.
recessed

29"

(73.7 cm)

max.

overall

height

30" (76.2 cm)

min. cabinet

1" (2.5 cm) top
of cutout to
bottom of upper
cabinet door

30" (76.2 cm) min.

cabinet width

30" (76.2 cm) min.

cabinet width

28-1/2"

(72.4 cm)

cutout

width

28-1/2"

(72.4 cm)

cutout

width

49-3/4"

(126.4 cm)

min.

cutout
height

14-3/4"

(37.5 cm)

bottom

of cutout

to floor

1-1/2" (3.8 cm)

min. bottom of

cutout to top of

cabinet door

28-1/2"

(72.4 cm)

cutout width

5-1/4" (13.3 cm)
bottom of cutout
to floor

27-3/4"
(70.5 cm)
min.
cutout
height

1-1/2"
(3.8 cm) min.
top of cutout
to underside
of countertop

1" (2.5 cm) top
of cutout to
bottom of upper
cabinet door

1-1/2"

(3.8 cm)

min.

bottom of

cutout to

top of

cabinet

door

32"

(81.3 cm)

bottom of

cutout to

floor

Single oven

undercounter

(without cooktop

installed above)

Double oven

Cabinet side view

Single oven

27-3/4"

(70.5 cm)

min.

cutout
height

23-1/4"

(59.1 cm) min.

cutout depth

23" (58.4 cm)

recessed oven

depth

recessed

oven

cabinet

oven
front

Important: Observe all governing codes
and ordinances.

Proper installation is your responsibility.
Have a qualified technician install this oven.

Oven location should be away from strong
draft areas, such as windows, doors and
strong heating vents.

Cabinet opening dimensions that are shown
must be used. Given dimensions provide
minimum clearance.

Recessed installation area must provide
complete enclosure around the recessed
portion of the oven.

Electrical ground is required. See “Electrical
requirements.”

Electrical supply junction box should be
located 3 inches (7.6 cm) maximum below the
support surface when oven is installed in a
wall cabinet. Drill a 1-inch minimum (2.5 cm)
diameter hole in the right rear or left rear
corner of the support surface to pass the
appliance cable through to the junction box.
For undercounter installation, it is
recommended that the junction box be
located in the adjacent right or left cabinet. If
installing the junction box on rear wall behind
oven, junction box must be recessed and
located in the upper or lower right or left
corner of cabinet.

Tool needed:

Parts supplied:

Cabinet filler kits are available from your dealer.
Use a matching color kit if oven is smaller than
your cabinet opening.

Single oven filler height is 3-5/16" (8.4 cm)

Black

— 4378941

White —

4378942

Almond — 4378943

Double oven filler height is 6-5/16" (16 cm)

Black —

4378947

White —

4378948

Almond — 4378949

29-3/4" (75.6 cm)

overall width

29-3/4" (75.6 cm)

overall width

It is the customer’s responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is
adequate and in conformance with National
Electrical Code, ANSI/NFPA 70 — latest
latest edition*, or Canadian Electrical Code,
C22.1-1982 and C22.2 No. 01982 (or latest
edition)** and all local codes and
ordinances.

Your safety and the safety of others are

very important.

We have provided many important safety
messages in this manual and on your appliance.
Always read and obey all safety messages.

This is the safety alert symbol.
This symbol alerts you to potential
hazards that can kill or hurt you and
others.

All safety messages will follow the safety alert
symbol and either the word “DANGER” or
“WARNING”. These words mean:

All safety messages will tell you what the
potential hazard is, tell you how to reduce the
chance of injury, and tell you what can happen if
the instructions are not followed.

You can be killed or seriously injured if you
don’t immediately follow instructions.

You can be killed or seriously injured if you
don’t follow instructions.

WARNING

DANGER

Copies of the standards listed may be obtained from:

* National Fire Protection Association

Batterymarch Park
Quincy, Massachusetts 02269

** CSA International

8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575

Advertising