F. hooking up the legend, Platinum ii, G. checking operation – Pentair Legend Platinum II Manuel d'utilisation

Page 8

Advertising
background image

LEGEND® PLATINUM II INSTALLATION MANUAL • MANUEL D’INSTALLATION LEGEND® PLATINUM II

F. Hooking up the Legend

®

Platinum II

1. Remove the Pressure Tester from the free end of

the Feeder Hose by unscrewing the Hose Nut.
Left hand thread (reverse), (see illustration,
previous page).

2. Place mender nut on Legend

®

Platinum II Swivel

Mast. Connect the open end of the Feed Hose
to the top of the Legend

®

Platinum II Swivel Mast

and secure with the mender nut. The arch of the
Feed Hose should align in the same direction
as the Swivel Mast, there should be no twist in
the Feed Hose after connection. (See illustration
below.)

3. Carefully twist lock the Sand & Silt debris bag

onto the top of the Legend

®

Platinum II Vacuum

Tube. Make sure there is a Rubber Debris Valve
attached to the top of the Vacuum Tube before
locking on the Sand & Silt bag, (this valve is
similar to a check valve to help keep debris
inside the bag when the water pressure is off).

FEED
HOSE

MENDER

NUT

THRUST

JET

HEAD FLOAT

FEED MAST

SWIVEL

4. Gently place the Legend

®

Platinum II in the pool.

Turn on the pool filtration pump.

5. Check to make sure the wheel RPM is between

25-32. See

page 5

for instructions on wheel

RPM.

G. Checking Operation

When operating correctly, the Legend

®

Platinum II

will travel in a random pattern throughout the pool,
vacuuming and sweeping the bottom. The climbing
ability of the Legend

®

Platinum II is dependent on

the pools structure and water flow coming into the
pool. It will perform more efficiently in pools without
sharp angles or curves in the transition from the floor
of the pool to the wall.

The Legend

®

Platinum II comes with a Twist Lock

Pressure Relief Valve (Wall Fitting). If the Legend

®

Platinum II is receiving too much water pressure, the
Pressure Relief Valve in the Wall Fitting will release
the excess water pressure.

Approximately every three minutes and 30 seconds
the Legend

®

Platinum II will go into a back-up mode.

The Back-Up Valve cycle time, while in the back-up
mode, is approximately 30 seconds, pulling the
Legend

®

Platinum II from problem areas.

The Sweep Hose operates in a gentle sweeping
motion to prevent debris from becoming trapped in
hard to reach corners of the pools.

If the Legend

®

Platinum II does not travel to all areas

of the pool, turn off the pool filtration pump and make
the necessary adjustments from the instructions on
the next page.

4